Main
Fluid connection type
G 1/4A (male) conforming to DIN 3852-E
controlled fluid
Fresh water (0-125 °C), air (-15-125 °C), gas (-15-125 °C), hydraulic oil (-15-125 °C)
Type of packing
Individual
pressure sensor name
XMLP
pressure sensor type
Pressure transmitter
Complementary
local display
Without
Product certifications
CERCMcULus
Product or component type
Electronic pressure sensors
[us] rated supply voltage
12...24 V DC SELV (voltage limits: 7-33 V)
Analogue output function
4...20 mA, 2-wire
Current consumption
< 23 mA
Quantity per set
Set of 1
Drift of the sensitivity
+/- 0,02 % of measuring range/°K
Drift of the zero point
+/- 0,03 % of measuring range/°K
Electrical circuit type
Control circuit
measurement accuracy
+/- 1.5 % of the measuring range
Operating position
Any position
repeat accuracy
+/- 0.1 % of the measuring range
Materials in contact with fluid
Fluorocarbon FPMceramicstainless steel AISI 316L
electrical connection
1 male connector EN 175301-803-A (ex DIN43650) 3 pins
Shock resistance
100 gn for 11 ms conforming to IEC 60068-2-27
Response time on output
<= 2 ms 92 % of full scale
Type of output signal
Analogue
Protection type
Load short-circuitreverse polarity
Environment
ip degree of protection
IP65 conforming to IEC 60529
Range of product
Telemecanique Pressure sensors XM
electromagnetic compatibility
Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...1000 MHz, radiated RF fields conforming to IEC 61000-4-6 10 V 0.15...80 MHz, electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 4 kV contact, 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 1 kV 42 Ohm, immunity to magnetic fields conforming to IEC 61000-4-8 100 A/m 50 Hz, electrical fast transient/burst immunity test conforming to IEC 61000-4-4 4 kV
standards
IEC 61326-2-3NSF ANSI 61
vibration resistance
20 gn (f = 10-2000 Hz) conforming to IEC 60068-2-6