Main
Fluid connection type
G 1/4A (male) conforming to DIN 3852-E
controlled fluid
Fresh water (0-125 °C), air (-30-125 °C), hydraulic oil (-30-125 °C)
Type of packing
Individual
pressure sensor name
XMEP
pressure sensor type
Pressure transmitter
Complementary
Accuracy
0.1 % of the measuring range
local display
Without
Product certifications
CEE2cULus
Product or component type
Electronic pressure sensors
[us] rated supply voltage
24 V DC SELV (voltage limits: 12-36 V)
Analogue output function
0...10 V, 3-wire
Current consumption
< 7 mA
Quantity per set
Set of 1
Drift of the sensitivity
+/- 0,02 % of measuring range/°K
Drift of the zero point
+/- 0,02 % of measuring range/°K
Electrical circuit type
Control circuit
measurement accuracy
+/- 0,5 % de la plage de mesure
Operating position
Any position
repeat accuracy
+/- 0.5 % of the measuring range
Materials in contact with fluid
Fluorocarbon FPMstainless steel AISI 316L
electrical connection
1 male connector AMP SUPERSEAL 1.5 3 pins
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Response time on output
<= 2 ms 10...90 % of full scale
Type of output signal
Analogue
Protection type
Load short-circuitreverse polarity
Environment
ip degree of protection
IP65 conforming to IEC 60529, IP67 conforming to IEC 60529
Range of product
Telemecanique Pressure sensors XM
electromagnetic compatibility
Electrostatic discharge immunity test conforming to ISO 10605 criteria A 15 kV air, 15 kV contact, susceptibility to electromagnetic fields conforming to ISO 11452-2 criteria A 100 V/m 200…2000 MHz, susceptibility to electromagnetic fields conforming to ISO 11452-4 criteria A 100 mA 20…400 MHz, susceptibility to conducted disturbances conforming to IEC 61000-4-6 criteria A 30 V 0.15...80 MHz, electrical fast transient/burst immunity test conforming to IEC 61000-4-4 criteria A 4 kV, susceptibility to conducted transient disturbances conforming to ISO 7637-2 criteria B level 3
standards
UL 61010-1IEC 61326-2-3ISO 13766ECE 10R-5EN 13309ISO 14982
vibration resistance
12 gn sinus (f = 20-520 Hz) test 4 conforming to ISO 16750-3, 18 gn random (f = 10-2000 Hz) test 4 conforming to ISO 16750-3