Default
Seeria
Plastikmodulaarne XB6
Main
product range
Harmony XB6
name of the device
XB6
type of product or equipment
Complete emergency stop push button
control unit type
mechanical release and latching
[ui] rated insulation voltage
250 V (pollution degree 3) conforming to EN/IEC 60947-1
reset
Turn to unlock
sale by indivisible quantity
1
Complementary
[ie] rated operational current
3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1
0.1 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1
0.22 A at 125 V, DC-13, R300 conforming to EN/IEC 60947-5-1
contact description
1 "O"
Handle front plate colour
30 mm
mounting diameter
16 mm
[uimp] rated impulse withstand voltage
4 kV conforming to EN/IEC 60947-1
product weight
0,041 kg
actuation stroke
1 mm (electrical state modified by "O")
2 mm (electrical state modified by "F")
3.5 mm (total stroke)
description of iso n°1 terminals
(21-22)NC
(13-14)NO
signaling unit head shape
round
bezel material
Plastic
electrical life
1000000 cycles, AC-15 at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13 at 230 V, operating rate operating speed <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
connection mode
Faston connectors, connection size: 2.8 x 0.5 mm
contact operation
Slow-action
type of lock
Climbed 200
contact material
Silver alloy (Ag/Ni)
mechanical endurance
100000 cycle
width (w)
30 mm
electrical reliability
Λ < 10exp(-8) at 5 V, 1 mA with 90% confidence level conforming to IEC 60947-5-4
actuation force
3.5 N electrical state modified by "N"
4.5 N electrical state modified by "O"
control unit profile
Red punch Ø 30 mm, unmarked
depth
77 mm
positive aperture
With conforming to EN/IEC 60947-5-1 appendix K
use of contacts
Standard
mounting position
All positions
short circuit protection
6 A cartouche fusible type gG
Environment
ip degree of protection
IP65 conforming to IEC 60529
product certificates
CCC
GOST
CSA
UL
class of protection against electric shock
Class II conforming to IEC 61140
operating ambient temperature
-25…70 °C
standards
JIS C8201-5-1
JIS C 852
EN/ISO 13850
EN/CEI 60947-5-5
CSA C22.2 No 14
UL 508
EN/CEI 60204-1
EN/CEI 60947-5-1
EN/CEI 60947-1
JIS C8201-1
storage room temperature
-40…70 °C
mechanical shock resistance
30 gn (duration = 18 ms) for acceleration on 1/2 sinusoid conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for acceleration on 1/2 sinusoid conforming to IEC 60068-2-27
vibration resistance
+/- 3 mm (f= 2...500 Hz) conforming to IEC 60068-2-6
5 gn (f= 2...500 Hz) conforming to IEC 60068-2-6
resistance to nema environment
NEMA 13 conforming to UL 50
NEMA 4 conforming to UL 50
NEMA 4X conforming to UL 50
NEMA 13 conforming to CSA C22.2 No. 94
NEMA 4X conforming to CSA C22.2 No. 94
NEMA 4 conforming to CSA C22 .2 No. 94
protective treatment
TC