Kõik kategooriad
Võrdle Ostukorv
LTMR100CFM - Mootori kontroller, TeSys T, Motor Management, CANopen, 6 loogilist sisendit, 3 releeloogika väljundit, 5 kuni 100A, 100 kuni 240VAC - Schneider Electric - Mootori kontroller, TeSys T, Motor Management, CANopen, 6 loogilist sisendit, 3 releeloogika väljundit, 5 kuni 100A, 100 kuni 240VAC - Schneider Electric - 0
LTMR100CFM - Mootori kontroller, TeSys T, Motor Management, CANopen, 6 loogilist sisendit, 3 releeloogika väljundit, 5 kuni 100A, 100 kuni 240VAC - Schneider Electric - Mootori kontroller, TeSys T, Motor Management, CANopen, 6 loogilist sisendit, 3 releeloogika väljundit, 5 kuni 100A, 100 kuni 240VAC - Schneider Electric - 0

LTMR100CFM – Schneider Electric

Tellitav
386,97 € KM-ta
479,84 € KM-ga
Mootori kontroller, TeSys T, Motor Management, CANopen, 6 loogilist sisendit, 3 releeloogika väljundit, 5 kuni 100A, 100 kuni 240VAC - Schneider Electric
479,84 €
SPETSIFIKATSIOONID
Default
Seeria TeSyS LT
Main
Device short name LTMR
Measurement current 5…100 A
Range TeSys
Product Name TeSys T
[ui] rated insulation voltage 690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
Complementary
compatibility code LTMR
Product certifications LROS (Lloyds register of shipping)
DNV
UL
EAC
GL
CCC
BV
ABS
KERI
ATEX
NOM
RINA
RMRoS
C-Tick
CSA
Connection pitch 5.08 mm
Handle front plate colour 61 mm
Product or component type Motor controller
tightening torque Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
[uimp] rated impulse withstand voltage 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
[us] rated supply voltage 100...240 V AC 50/60 Hz
Current consumption 8...62.8 mA
Connections - terminals Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
current state 0 guaranteed Logic input: 0...40 V and <= 15 mA for 25 ms
Associated fuse rating 4 A gG for output
0.5 A gG for control circuit
Bus type CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, SUB-D 9 with 4 twisted shielded pairs cable
CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, terminal block with 4 twisted shielded pairs cable
current state 1 guaranteed Logic input: 79...264 V and >= 2 mA for 25 ms
Device application Equipment monitoring and control
Contacts type and composition 1 NO + 1 NC fault signal
3 NO
input current 3.1 mA at 100 V
7.5 mA at 240 V
Load current 5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
width (w) 91 mm
mechanical robustness Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
supply voltage limits 93.5…264 V AC
Net weight 0.53 kg
measurement accuracy 5...15 % earth fault current internal measurement
1 % voltage (100...830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
5 % active and reactive power
0,02 current
communication port protocol CANopen
depth 122.5 mm
Pollution degree 3
Maximum operating rate 1800 cyc/h
Logic input number 6
Maximum output switching frequency 2 Hz
Metering type Earth-fault current
Phase current I1, I2, I3 RMS
Imbalance current
Temperature
Average current Iavg
Network and machine diagnosis type Event recording
Trip history information
Starting current and time
Running hours counter/operating time
Motor control command recording
Remaining operating time before overload tripping
Fault recording
Phase fault and earth fault trip counters
Waiting time after overload tripping
Trip context information
Permissible power 480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
Short-circuit withstand 100 kA conforming to EN/IEC 60947-4-1
Protection type Thermal protection
Locked rotor
Phase failure
Earth-leakage protection
Overload (long time)
Power factor variation
Phase unbalance
Load fluctuation
Thermal overload protection
Reverse polarity protection
Overload
Web services Web server
Environment
Ambient air temp for storage/transportation -40…80 °C
ip degree of protection IP20
operating altitude <= 2000 m without derating
ambient air temperature for operation -20…60 °C
electromagnetic compatibility Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
overvoltage category III
standards IEC 60947-4-1
CSA C22.2 No 14
IACS E10
EN 60947-4-1
UL 508
fire resistance 650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
protective treatment 12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
KKK ja hinna lisateave

Võta meiega ühendust

Professionaalne elektriseadmete müük Eestis, Lätis, Leedus ja Soomes. Sertifitseeritud madalpinge komponendid, kaitselülitid, kontaktorid ja tööstusautomaatika lahendused. Sama päeva hinnapakkumised ja kiire tarne Baltikumis ja Soomes

Baltelec
+372 5326 4976

E–R 9:00–17:00

info@baltelec.ee

Vastame 2 tunni jooksul

LTMR100CFM on lahendus kategooriast Mootorihaldus, mis on mõeldud suurettevõtetele. BaltElec tegeleb hulgimüügi ja distributsiooniga Eestis, Lätis, Leedus ja Soomes.

  • Originaal Schneider Electric toode, vastavusdokumendid päringu alusel.
  • Projektihind – küsi pakkumist suuremate koguste jaoks (võimalik, et sätestame MOQ).
  • Kiire tarne Baltikumis ning Soomes; koostöö tunnustatud kulleritega.
  • Tehniline tugi ja ettepanekud sobivuse kohta vastavalt Sinu rakendusele.

Hind: Küsi projektipakkumist. Hind sõltub kogusest, tarne- ja maksetingimustest.

KKK tootele LTMR100CFM - Schneider Electric

Hiljuti vaadatud
LTMR100CFM - Schneider Electric
Mootori kontroller, TeSys T, Motor Management, CANopen, 6 loogilist sisendit, 3 releeloogika väljundit, 5 kuni 100A, 100 kuni 240VAC
386,97 € KM-ta
479,84 € KM-ga
Tellitav