Main
Range
TeSys
[uc] control circuit voltage
24...1000 V AC 40...400 Hz with coil LX1/LX9
24...460 V DC with coil LX4
100...250 V AC 50/60 Hz with coil LXE
100...380 V with coil LXE
job category
AC-3
AC-4
AC-1
name of the device
LC1F
switch application
Resistive load (AC-1)
Motor control (AC-3)
type of product or equipment
contactor
Product Name
TeSys F
[ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 gr C
composition of the power pole contacts
3F
motor power kW
132 kW at 380...400 V AC 50/60 Hz (AC-3)
140 kW at 415 V AC 50/60 Hz (AC-3)
140 kW at 440 V AC 50/60 Hz (AC-3)
147 kW at 1000 V AC 50/60 Hz (AC-3)
160 kW at 500 V AC 50/60 Hz (AC-3)
75 kW at 220...240 V AC 50/60 Hz (AC-3)
160 kW à 660...690 V AC 50/60 Hz (AC-3)
51 kW à 400 V AC 50/60 Hz (AC-4)
average impedance
0,3 mOhm - Ith 350 A 50 Hz
Complementary
[ie] rated operational current
350 A (at <40°C) at <= 440 V AC AC-1
265 A (at <55°C) at <= 440 V AC AC-3
[ue] rated operational voltage
<= 1000 V AC-1
<= 690 V AC-3
<= 690 V AC-4
<= 460 V CC
compatibility code
LC1F
[ics] rated service breaking capacity
2120 A conforming to IEC 60947-4-1
[icw] rated short-time withstand current
2200 A at <40°C - 10 s
1230 A at <40°C - 30 s
950 A at <40°C - 1 min
620 A at <40°C - 3 min
480 A at <40°C - 10 min
[ith] conventional thermal current
350A at <40°C)
caliber of the fuse to be associated
315 A aM at <= 440 V
400 A gG at <= 440 V
Handle front plate colour
203 mm
tightening torque
Power circuit: 35 Nm
Remote control: 1.2 Nm
Remote control: 0.6 Nm
[uimp] rated impulse withstand voltage
8 kV
average fuel consumption when going
8…10 VA
3.68…4.53 VA
4.5…7.0 VA
2.5…4.0 VA
product weight
8,54 kg
average consumption on call going
600…700 VA, 40...400 Hz cos phi 0.9 (at 20 °C) with LX1/LX9 coil
655…803 VA (at 20 °C) with LX4 coil
300…350 VA, 50/60 Hz cos phi 0.5 (at 20 °C) with LXE coil
300…310 VA (at 20 °C) with LXE coil
connection mode
Power circuit: bar 2 cable(s) - busbar section: 32 x 4 mm
Power circuit: ring terminals 1 cable(s) 240 mm²
Power circuit: connector 1 cable(s) 240 mm²
Power circuit : connection by bolting
Remote control: screw clamp terminals 1 cable(s) 1...4 mm² flexible without cable end
Remote control: screw clamp terminals 2 cable(s) 1...4 mm² flexible with cable end
Remote control: screw terminal blocks clamp 1 cable(s) 1...4 mm²flexible with cable end
Remote control: screw clamp terminals 2 cable(s) 1...2.5 mm²rigid without cable end
Remote control: screw clamp terminals 1 cable(s) 1... 4 mm²
Remote control: screw clamp terminals 2 cable(s) 1...4 mm²
Remote control: screw clamp terminals 1.0 cable(s) 0.2...2.5 mm²flexible without cable end
Remote control: screw clamp terminals 1.0 cable(s) 0.25...2.5 mm²flexible with cable end cable
cross-section Remote control: screw clamp terminals 1.0 cable(s) 0.2...2.5 mm²rigid without cable end
control circuit voltage range
Operational: 0.85…1.1 Uc AC 40...400 Hz
Level drop: 0.35...0.55 Uc AC 40...400 Hz
Operational: 0.85…1.1 Uc DC
Level drop : 0.15...0.2 Uc DC
Operational: 85...275 V AC 50/60 Hz
Dropout: 0...60 V AC 50/60 Hz
Operational: 85...418 V DC
Dropout : 0...45 V DC
mechanical endurance
10 Mcycles
width (w)
201,5 mm
mechanical robustness
Open contactor vibrations: 2 Gn, 5 to 300 Hz
Closed contactor vibrations: 5 Gn, 5 to 300 Hz
Open contactor shocks: 6 Gn for 1/2 sine wave (11 ms)
Closed contactor shocks: 15 Gn for 1/2 sine wave( 11ms)
rated rms inrush power
2650 A AC conforming to IEC 60947-4-1
depth
213 mm
mounting bracket
Platinum
operating time
40…65 ms closing for with LX1/LX9 coil
100…170 ms opening for with LX1/LX9 coil
40…50 ms closing for with LX4 coil
40…65 ms opening for with LX4 coil
40…80 ms closing for with LXE
6 coil ...54 ms opening for with LXE coil
power loss per pole
37 W AC-1
21 W AC-3
max command speed
2400 cycles/h at <55°C
Poles description
3P
Environment
ip degree of protection
IP20 front face with protectors conforming to IEC 60529
IP20 front face with protectors conforming to VDE 0106
operating altitude
3000 m without current reduction
product certificates
ABS
CB
DNV
RMRoS
UL
CSA
RINA
LROS (Lloyds register of shipping)
BV
UKCA
ambient air temperature for operation
-40…70 °C
operating ambient temperature
-5…55 °C
overvoltage category
III
standards
CEI 60947-1
CEI 60947-4-1
JIS C8201-4-1
EN 60947-1
EN 60947-4-1
thermal dissipation
8 W
2,2…2,5 W
storage room temperature
-60…80 °C
protective treatment
TH