Kõik kategooriad
Võrdle Ostukorv
LC1DT40BD - Kontaktor, TeSys Deca, 4P(4 NO), AC-1, 0 kuni 440V, 40A, 24V DC standardspiraal. - Schneider Electric - Kontaktor, TeSys Deca, 4P(4 NO), AC-1, 0 kuni 440V, 40A, 24V DC standardspiraal. - Schneider Electric - 0
LC1DT40BD - Kontaktor, TeSys Deca, 4P(4 NO), AC-1, 0 kuni 440V, 40A, 24V DC standardspiraal. - Schneider Electric - Kontaktor, TeSys Deca, 4P(4 NO), AC-1, 0 kuni 440V, 40A, 24V DC standardspiraal. - Schneider Electric - 0

LC1DT40BD – Schneider Electric

Tellitav
EAN: 3389110247855
71,31 € KM-ta
88,42 € KM-ga
Kontaktor, TeSys Deca, 4P(4 NO), AC-1, 0 kuni 440V, 40A, 24V DC standardspiraal. - Schneider Electric
88,42 €
SPETSIFIKATSIOONID
Default
Seeria TeSyS Deca kontaktorid
Main
product range TeSys D
TeSys Deca
Range TeSys
TeSys Deca
[uc] control circuit voltage 24 V CC
job category AC-1
name of the device LC1D
switch application Resistive load (AC-1)
type of product or equipment contactor
[ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signaling circuit: 690 V conforming to IEC 60947-1
Signaling circuit: 600 V CSA certified
Signaling circuit: 600 V UL certified
Power circuit: 690 V conforming to IEC 60947-4-1
control circuit type CC standard
composition of the power pole contacts 4F
average impedance 2 mOhm - Ith 40 A 50 Hz for power circuit
Complementary
[ie] rated operational current 40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
compatibility code LC1D
[ics] rated service breaking capacity 450 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current 50 A at <40°C - 10 min for
120 A power circuit at <40°C - 1 min for
240 A power circuit at <40°C - 10 s for
380 A power circuit at <40°C - 1s for
100 A power circuit - 1s for
120 A signaling circuit - 500 ms for
140 A signaling circuit - 100 ms for signaling circuit
[ith] conventional thermal current 10 A at <60°C) for signaling circuit
40 A at <60°C) for power circuit
caliber of the fuse to be associated 10 A gG for signaling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V type 1 coordination for power circuit
40 A gG at <= 690 V type 2 coordination for power circuit
average consumption on hold in w 5.4W at 20°C
Handle front plate colour 91 mm
tightening torque Remote control: 1.7 Nm - on EverLink BTR screw connectors - with Ø 6 mm flat screwdriver
Remote control: 1.7 Nm - on EverLink BTR screw connectors - with Phillips No. 2 screwdriver
Power circuit: 1.7 Nm - on EverLink BTR screw connectors - with flat screwdriver Ø 6 mm
Power circuit: 1.7 Nm - on EverLink BTR screw connectors - with Phillips n° 2 screwdriver
Remote control: 1.7 Nm - on EverLink BTR screw connectors - with n°2 pozidriv screwdriver Power
circuit: 2.5 Nm - on EverLink BTR screw connectors - with n°2 pozidriv screwdriver
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
auxiliary contacts 1 "O" + 1 "F"
minimum switching current 5 mA for signaling circuit
product weight 0,425 kg
type of auxiliary contacts mechanically linked type 1 NC + 1 NO conforming to IEC 60947-5-1
1 NC mirror contact type conforming to IEC 60947-4-1
contact compatibility M7
electrical life 1.4 Mcycles 40 A AC-1 at Ue <= 440 V
connection mode Remote control: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Remote control: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end
Remote control: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end
Remote control: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Remote control: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end
Remote control: screw clamp terminals 2 1…4 mm² - cable stiffness: rigid without cable end
Power circuit: connector 1 2.5…10 mm² - cable stiffness: flexible without cable end
Power circuit: connector 2 2, 5...10 mm² - cable stiffness: flexible without cable end
Power circuit: connector 1 2.5…10 mm² - cable stiffness: flexible with ferrule
Power circuit: connector 2 2.5…10 mm² - cable stiffness: flexible with ferrule
Power circuit: connector 1 2.5…10 mm² 16 mm² - cable stiffness: solid without cable end
Power circuit: connector 2 2.5...16 mm² - cable stiffness: solid without cable end
control circuit voltage range 0.1 to 0.25 Uc -40…70 °C DC level drop
0.7 to 1.25 Uc -40…60 °C DC operational
1...1.25 Uc 60…70 °C DC operational
mechanical endurance 30 Mcycles
width (w) 45 mm
mechanical robustness Contactor open vibrations (2 Gn, 5 to 300 Hz)
Contactor closed vibrations (4 Gn, 5 to 300 Hz)
Contactor closed shocks (15 Gn for 11 ms)
Contactor open shocks (8 Gn for 11 ms)
Flame retardance V1 conforming to UL 94
time constant 28 ms
rated rms inrush power 140 A AC for signaling circuit conforming to IEC 60947-5-1
250 A DC for signaling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947
depth 107 mm
mounting bracket Platine
Rail
frequency With
maximum inrush power in w 5.4W (at 20°C)
signaling circuit frequency 25 to 400 Hz
operating time 16…24 ms opening
53.55…72.45 ms closing
power loss per pole 3,2 W AC-1
security reliability level B10d = 1369863 contactor cycle with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 contactor cycle with mechanical load conforming to EN/ISO 13849-1
max command speed 3600 cycles/h at <60°C
minimum switching voltage 17 V for signaling circuit
non-overlap time 1.5 ms on de-
energization between NC and NO contact 1.5 ms on excitation between NC and NO contact
coil technology Built-in bi-directional peak limit diode suppressor
Poles description 4P
Environment
degree of pollution 3
ip degree of protection IP20 front face conforming to IEC 60529
operating altitude 0...3000 m
product certificates CSA
UL
RINA
GOST
LROS (Lloyds register of shipping)
BV
GL
DNV
CCC
ambient air temperature for operation -40…60 °C
60…70 °C with current reduction
overvoltage category III
standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
CEI 60947-4-1
CEI 60947-5-1
UL 508
CEI 60335-1
fire resistance 850 °C conforming to IEC 60695-2-1
climatic resistance conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
protective treatment TH conforming to IEC 60068-2-30
insulation resistance > 10 MΩ for signaling circuit
KKK ja hinna lisateave

Võta meiega ühendust

Professionaalne elektriseadmete müük Eestis, Lätis, Leedus ja Soomes. Sertifitseeritud madalpinge komponendid, kaitselülitid, kontaktorid ja tööstusautomaatika lahendused. Sama päeva hinnapakkumised ja kiire tarne Baltikumis ja Soomes

Baltelec
+372 5326 4976

E–R 9:00–17:00

info@baltelec.ee

Vastame 2 tunni jooksul

LC1DT40BD Schneider Electric on lahendus kategooriast Tööstuslikud kontaktorid, mis on mõeldud ettevõtetele. BaltElec tegeleb mahupõhise müügi ja toodete levitamisega Eestis, Lätis, Leedus ja Soomes.

  • Autentne Schneider Electric toode, sertifikaadid ja vastavusdokumendid saadaval.
  • Mahupõhine hinnastus – küsi pakkumist suuremate koguste jaoks (võimalik, et sätestame MOQ).
  • Kiire tarne Baltikumis ning Soomes; koostöö logistikapartneritega.
  • Tehniline tugi ja ettepanekud sobivuse kohta vastavalt Sinu rakendusele.

Hind: Küsi eripakkumist. Hind sõltub kogusest, tarne- ja maksetingimustest.

KKK tootele LC1DT40BD - Schneider Electric

Hiljuti vaadatud
LC1DT40BD - Schneider Electric
Kontaktor, TeSys Deca, 4P(4 NO), AC-1, 0 kuni 440V, 40A, 24V DC standardspiraal.
71,31 € KM-ta
88,42 € KM-ga
Tellitav