SPETSIFIKATSIOONID
Default
Seeria TeSyS K
Main
Contactor application Resistive load
Motor control
Device short name LC1K
Range TeSys
[uc] control circuit voltage 24 V DC
Product Name TeSys K
[ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Power circuit: 750 V conforming to VDE 0110 group C
Power circuit: 690 V conforming to BS 5424
Power circuit: 690 V conforming to NF C 20-040
control circuit type DC low consumption
motor power kW 1.5 kW at 220...230 V AC 50/60 Hz
2.2 kW at 380...415 V AC 50/60 Hz
3 kW at 500...600 V AC 50/60 Hz
3 kW at 440/500 V AC 50/60 Hz
3 kW at 660/690 V AC 50/60 Hz
0.37 kW at 115 V AC 50/60 Hz
0.75 kW at 220 V AC 50/60 Hz
average impedance 3 mOhm - Ith 20 A 50 Hz for power circuit
Complementary
[ie] rated operational current 6 A at <= 440 V AC AC-3 for power circuit
[ue] rated operational voltage Power circuit: 690 V AC 50/60 Hz
Signalling circuit: <= 690 V AC 50/60 Hz
[ics] rated service breaking capacity 110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220...230 V conforming to IEC 60947
110 A at 380...400 V conforming to IEC 60947
70 A at 660...690 V conforming to IEC 60947
[icw] rated short-time withstand current 90 A 50 °C - 1 s for power circuit
85 A 50 °C - 5 s for power circuit
80 A 50 °C - 10 s for power circuit
60 A 50 °C - 30 s for power circuit
45 A 50 °C - 1 min for power circuit
40 A 50 °C - 3 min for power circuit
20 A 50 °C - >= 15 min for power circuit
80 A - 1 s for signalling circuit
90 A - 500 ms for signalling circuit
110 A - 100 ms for signalling circuit
[ith] conventional thermal current 20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Product certifications CB Scheme
CCC
UL
CSA
EAC
CE
UKCA
Handle front plate colour 58 mm
Product or component type Contactor
tightening torque Power circuit: 0.8…1.3 N.m - on lugs-ring terminals - with screwdriver 3.2 mm flat Ø 6 mm
Power circuit: 0.8…1.3 N.m - on lugs-ring terminals - with screwdriver 3.2 mm Philips No 2
Power circuit: 0.8…1.3 N.m - on lugs-ring terminals pozidriv No 2
[uimp] rated impulse withstand voltage 8 kV
Auxiliary contact composition 1 NO
Connections - terminals Power circuit: lugs-ring terminals (external diameter: 7 mm)
minimum switching current 5 mA for signalling circuit
Associated fuse rating 25 A gG at <= 440 V for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
Auxiliary contacts type type instantaneous 1 NO
Device application Control
Control circuit voltage limits Operational: 0.7...1.3 Uc (at <50 °C)
Drop-out: >= 0.10 Uc (at <50 °C)
width (w) 45 mm
mechanical robustness Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Flame retardance V0 conforming to UL 94
Heat dissipation 1.8 W
Net weight 0.235 kg
Hold-in power consumption in w 1.8 W at 20 °C
Mounting support Rail
Plate
depth 57 mm
inrush power in w 1.8 W (at 20 °C)
mechanical durability 30 Mcycles
electrical durability 1.3 Mcycles 6 A AC-3 at Ue <= 440 V
Irms rated making capacity 110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
Maximum operating rate 3600 cyc/h
operating time 10...20 ms coil de-energisation and NO opening
30...40 ms coil energisation and NO closing
minimum switching voltage 17 V for signalling circuit
Power pole contact composition 3 NO
Non overlap distance 0.5 mm
coil technology With integral suppression device
Poles description 3P
Utilisation category AC-1
AC-3
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Signalling circuit frequency <= 400 Hz
Environment
Ambient air temp for storage/transportation -50…80 °C
ip degree of protection IP20 conforming to VDE 0106
operating altitude 2000 m without derating
Permissible ambient air temperature around the device -40…70 °C at Uc
overvoltage category III
standards EN/IEC 60947-4-1
GB/T 14048.4
UL 60947-4-1
CSA C22.2 No 60947-4-1
JIS C8201-4-1
protective treatment TC conforming to IEC 60068
TC conforming to DIN 50016
insulation resistance > 10 MOhm for signalling circuit
KKK ja hinna lisateave

Võta meiega ühendust

Professionaalne elektriseadmete müük Eestis, Lätis, Leedus ja Soomes. Sertifitseeritud madalpinge komponendid, kaitselülitid, kontaktorid ja tööstusautomaatika lahendused. Sama päeva hinnapakkumised ja kiire tarne Baltikumis ja Soomes

Baltelec
+372 5326 4976

E–R 9:00–17:00

info@baltelec.ee

Vastame 2 tunni jooksul

Schneider Electric LC1K06106BLS207 on toode kategooriast Tööstuslikud kontaktorid, mis on mõeldud suurettevõtetele. BaltElec tegeleb hulgimüügi ja distributsiooniga Eestis, Lätis, Leedus ja Soomes.

  • Autentne Schneider Electric toode, sertifikaadid ja vastavusdokumendid saadaval.
  • Mahupõhine hinnastus – küsi pakkumist suuremate koguste jaoks (võimalik, et sätestame MOQ).
  • Tõhus ja kiire logistika Baltikumis ning Soomes; koostöö logistikapartneritega.
  • Tehniline tugi ja nõustamine valikul vastavalt Sinu rakendusele.

Hind: Küsi eripakkumist. Hind sõltub kogusest, tarne- ja maksetingimustest.

KKK tootele LC1K06106BLS207 - Schneider Electric

Hiljuti vaadatud
LC1K06106BLS207 - Schneider Electric
Kontaktor, TeSys K, 3P, AC-3 <=440V 6A, 1NO abipool, 24V DC madala tarbimisega mähis.
36,63 € KM-ta
45,43 € KM-ga
Tellitav