Main
product range
OsiSense XC
[ithe] thermal current under enclosure
10 A
product specific application
Handling
name of the device
XC1AC
type of product or equipment
Limit switch
control unit type
Reinforced metal return roller lever
range name
Special format
sensor shape
-
[ui] rated insulation voltage
500 V AC conforming to IEC 60947-5-1
500 V AC conforming to NF C 20-040
600 V DC conforming to IEC 60947-5-1
600 V DC conforming to NF C 20-040
600 V AC conforming to conforming to CSA C22.2 No 14
600 V DC conforming to CSA C22.2 No 14
control head movement
Linear
head type
Plunger head
kind of approach
Lateral approach, 2 directions
Complementary
contact description
1 F/O
Handle front plate colour
139 mm
cable entry
3 entries tapped for Pg 13.5 cable gland, external cable diameter: 9…12 mm
matter
Metal
minimal actuation effort
29 N
product weight
0,595 kg
description of iso n°1 terminals
(11-12)NC
(13-14)NO
fixing method
By the body
electrical life
1000000 cycles, AC-15 f = 50/60 Hz, inductive load type, 110 V, 900 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, AC-15 f = 50/60 Hz, inductive load type, 230 V, 1900 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, AC-15 f = 50/60 Hz, inductive load type, 48 V, 450 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5- 1 appendix C
1000000 cycles, DC-13, inductive load type, 110 V, 100 W, operating rate <60 cyc/min, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, DC-13, inductive load type, 230 V, 95 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
1000000 cycles, DC- 13, inductive load type, 48 V, 100 W, operating rate <60 cyc/min, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, AC-15 f = 50/ 60 Hz, inductive load type, 110 V, 350 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, AC-15 f = 50 /60 Hz, inductive load type, 230 V, 430 VA, operating rate <60 cyc/min, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, AC-15 f = 50/60 Hz, inductive load type, 48 V, 170 VA, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, DC-13, inductive load type, 110 V, 40 W, operating rate <60 cyc/min, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, DC -13, inductive load type, 230 V, 33 W, operating rate <60 cyc/min, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
3000000 cycles, DC-13, inductive type load, 48 V, 35 W, operating rate <60 cyc/min, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
contact operation
Slow-action
form of insulation between contacts
For
mechanical endurance
10000000 cycle
width (w)
77 mm
crankcase type
Fixed
attack move
With 30° cam
position name
1
depth
44 mm
maximum attack speed
1 m/s from left
0.5 m/s from right
positive aperture
Without
electrical connection
Screw clamp terminals, clamping capacity: 1 x 0.5...1 x 2.5 mm²
mounting position
All positions
maximum resistance between terminals
8 mOhm
short circuit protection
10 A cartouche fusible, type gG
Poles description
1