Main
product range
Telemecanique XY2C cable emergency stop
[ithe] thermal current under enclosure
6 A
reliability data
B10d = 4000000 value for a lifetime of 20 years limited by wear or contact conforming to IEC 60947-5-5
name of the device
XY2CH
type of product or equipment
Rope emergency stop lock
[ui] rated insulation voltage
400 V (pollution degree 3) conforming to EN/IEC 60947-1
300 V conforming to UL 508
300 V conforming to CSA C22.2 No 14
security level
Up to PL = e with appropriate monitoring system and correct wiring conforming to EN/ISO 13849-1
Up to category 4 with appropriate monitoring system and correct wiring conforming to EN/ISO 13849-1
Up to SIL 3 with appropriate monitoring system and correct wiring conforming to EN/IEC 61508
reset
By initialized push button
Complementary
[ie] rated operational current
0.1 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1 appendix A
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1 appendix A
compatibility code
XY2CH
contact description
2 "O" + 1 "F"
number of cables
1
number of cable entries
3 tapped entry for 1/2" NPT cable entry
tightening torque
0,8…1,2 N.m
[uimp] rated impulse withstand voltage
4 kV conforming to EN/IEC 60947-1
product weight
0,865 kg
description of iso n°1 terminals
(13-14)NO
(21-22)NC
(31-32)NC
marking
THIS
Housing colour
Rouge RAL 3000
connection mode
Screw clamp terminals, 1 x 0.34...1 x 1 mm²
Screw clamp terminals, 1 x 0.34...2 x 0.75 mm²
contact operation
Slow-action
distance between cable supports
5 m
body material
the burdens
mechanical endurance
800000 cycle
Local signalling
Without pilot light
maximum trip cable length
30 m
cover material
stainless steel
positive aperture
With conforming to EN/IEC 60947-5-1
trigger cable anchor point
Right or left side
maximum resistance between terminals
25 MΩ conforming to EN/IEC 60255-7 category 3
25 MΩ conforming to NF C 93-050 method A
short circuit protection
6 A cartridge fuse type gG conforming to EN/IEC 60269
Environment
ip degree of protection
IP65 conforming to IEC 60529
product certificates
UL Category NISD CSA
CCC Emergency Stop Devices
operating ambient temperature
-25…70 °C
overvoltage category
Class I conforming to EN/IEC 61140
Class I conforming to NF C 20-030
standards
EN/IEC 60204-1
EN/IEC 60947-5-5
Machinery Directive 2006/42/EC
EN/ISO 13850
UL 508
Work Equipment Directive 2009/104 / CE
EN/IEC 60947-5-1
CSA C22.2 No. 14
storage room temperature
-40…70 °C
mechanical shock resistance
50 gn 11 ms conforming to EN/IEC 60068-2-27
vibration resistance
10 gn (f= 10...150 Hz) conforming to EN/IEC 60068-2-6
protective treatment
TC