Main
product range
Telemecanique XY2C cable emergency stop
[ithe] thermal current under enclosure
10 A
reliability data
B10d = 300000 value for a lifetime of 20 years limited by wear or contact conforming to IEC 60947-5-5
name of the device
XY2CED
type of product or equipment
Double rope emergency stop
[ui] rated insulation voltage
500 V (pollution degree 3) conforming to EN/IEC 60947-1
300 V conforming to UL 508
300 V conforming to CSA C22.2 No 14
security level
Up to PL = e with appropriate monitoring system and correct wiring conforming to EN/ISO 13849-1
Up to category 4 with appropriate monitoring system and correct wiring conforming to EN/ISO 13849-1
Up to SIL 3 with appropriate monitoring system and correct wiring conforming to EN/IEC 61508
reset
By recessed push button
Complementary
[ie] rated operational current
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
compatibility code
XY2CED
contact description
2 x (1 "O" + 1 "F")
number of cables
2
number of cable entries
3 smooth hole for Pg 13.5 or ISO M21 cable gland
tightening torque
0,8…1,2 N.m
[uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-1
product weight
1,9 kg
description of iso n°1 terminals
(21-22)NC
(13-14)NO
marking
THIS
Bellow material
Nitrile
Housing colour
Rouge RAL 3000
connection mode
Screw clamp terminals, 1 x 0.5...2 x 1.5 mm²
contact operation
Slow-action
distance between cable supports
3…5 m
body material
the burdens
mechanical endurance
60000 cycle
Local signalling
Without pilot light
maximum trip cable length
2 100 m
cover material
stainless steel
positive aperture
With conforming to EN/IEC 60947-5-1
trigger cable anchor point
Right and left sides
maximum resistance between terminals
25 MΩ conforming to EN/IEC 60255-7 category 3
short circuit protection
10 A cartridge fuse type gG conforming to EN/IEC 60269
Environment
ip degree of protection
IP66 conforming to IEC 60529
product certificates
UL category emergency stop devices NISD
CSA
CCC
EAC
operating ambient temperature
-25…70 °C
overvoltage category
Class I conforming to EN/IEC 61140
standards
CSA C22.2 No 14
EN/ISO 13850
EN/IEC 60947-5-5
UL 508
Work Equipment Directive 2009/104 / CE
EN/IEC 60947-5-1
EN/IEC 60204-1
Machinery Directive 2006/42 /EC
storage room temperature
-40…70 °C
mechanical shock resistance
50 gn 11 ms conforming to EN/IEC 60068-2-27
vibration resistance
10 gn (f= 10...300 Hz) conforming to EN/IEC 60068-2-6
protective treatment
TC