Main
conception
ComPacT
product range
Telemecanique XCS safety switches
[ithe] thermal current under enclosure
10 A
reliability data
B10d = 5000000 value for a life of 20 years limited by wear or contact
type of product or equipment
Safety switch
[ui] rated insulation voltage
300 V conforming to UL 508
500 V conforming to EN/IEC 60947-1
300 V conforming to CSA C22.2 No 14
security level
Up to category 4 with suitable monitoring system and correct wiring conforming to EN/ISO 13849-1
Up to PL = e with suitable monitoring system and correct wiring conforming to EN/ISO 13849-1
Up to SIL 3 with appropriate monitoring system and correct wiring conforming to EN/IEC 61508
component name
XCSPA
head type
Key turret
Complementary
[ie] rated operational current
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1
contact description
2 "O"
Handle front plate colour
94 mm
[uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-5-1
forced actuator for retractable
10 N
cable entry
1 threaded entry for M16 x 1.5
matter
Plastic
product weight
0,11 kg
cable outer diameter
7…10 mm
minimum force for positive opening
15 N
contact operation
Snap action
body material
Polyamide
mechanical endurance
1000000 cycle
width (w)
30 mm
isolation
Double isolation
head material
Polyamide
depth
30 mm
maximum attack speed
0,5 m/s
minimum attack speed
0,01 m/s
optional locks
Without actuator lock
positive aperture
With "NC" contact
electrical connection
Terminal block, clamping capacity: 1 x 0.34...2 x 1.5 mm²
max command speed
10 cyc/min for maximum viability
short circuit protection
10 A cartouche fusible type gG (gl)
Poles description
2
Environment
ip degree of protection
IP67 conforming to EN/IEC 60529
IP67 conforming to EN/IEC 60947-5-1
product certificates
UL
CSA
class of protection against electric shock
Class II conforming to EN/IEC 61140
operating ambient temperature
-25…70 °C
standards
EN/CEI 60204-1
EN 1088/ISO 14119
EN/ISO 12100
CSA C22.2 No 14
UL 508
EN/CEI 60947-5-1
storage room temperature
-40…70 °C
mechanical shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
vibration resistance
5 gn (f= 10...500 Hz) conforming to IEC 60068-2-6
protective treatment
TC