Main
product range
Telemecanique XC Standard limit switches
name of the device
XCMN
type of product or equipment
Limit switch
control unit type
Pusher with metal return roller
range name
Format standard
sensor shape
Miniature
cable length
1 m
[ui] rated insulation voltage
300 V (pollution degree 3) conforming to UL 508
400 V (pollution degree 3) conforming to IEC 60947-5-1
300 V (pollution degree 3) conforming to CSA C22.2 No 14
control head movement
Linear
head type
Plunger head
kind of approach
Lateral approach, 2 directions
Complementary
cable composition
4 x 0,75 mm²
contact description
1 "O" + 1 "F"
Handle front plate colour
70,4 mm
[uimp] rated impulse withstand voltage
4 kV conforming to IEC 60664
4 kV conforming to IEC 60947-1
matter
Plastic
minimal actuation effort
7 N
product weight
0,08 kg
fixing method
By the body
electrical life
5000000 cycles, DC-13, 120 V, 1 W, operating rate <60 cyc/min, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/min, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/ min, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
minimum force for positive opening
35 N
contact operation
Snap action
form of insulation between contacts
Zb
body material
Plastic
mechanical endurance
5000000 cycle
width (w)
30 mm
crankcase type
Fixed
isolation
PvR
attack move
With 30° cam
contact code designation
B300, AC-15 (Ue = 240 V), Ie = 1.5 A conforming to EN/IEC 60947-5-1 appendix A
R300, DC-13 (Ue = 250 V), Ie = 0.1 A se conforming to EN/IEC 60947-5-1 appendix A
head material
the burdens
depth
16 mm
maximum attack speed
0,5 m/s
positive aperture
With
electrical connection
fixed cable
maximum resistance between terminals
25 MΩ conforming to IEC 60255-7 category 3
short circuit protection
6 A cartouche fusible, type gG
Poles description
2
Environment
ip degree of protection
IP65 conforming to IEC 60529
product certificates
CSA
CCC
UL
class of protection against electric shock
Class II conforming to IEC 61140
Class II conforming to NF C 20-030
operating ambient temperature
-25…70 °C
standards
CSA C22.2 No 14
UL 508
EN/CEI 60204-1
EN/CEI 60947-5-1
shock resistance ik
IK04 conforming to EN 50102
storage room temperature
-40…70 °C
mechanical shock resistance
25 gn for 18 ms conforming to IEC 60068-2-27
vibration resistance
5 gn (f= 10...500 Hz) conforming to IEC 60068-2-6
protective treatment
TC