Complementary
[ie] rated operational current
3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
[ith] conventional thermal current
10 A conforming to EN/IEC 60947-5-1
Handle front plate colour
47 mm
mounting diameter
22 mm
tightening torque
0.8...1.2 Nm conforming to EN 60947-1
[uimp] rated impulse withstand voltage
6 kV conforming to EN 60947-1
product weight
0,17 kg
actuation stroke
1.5 mm (electrical state modified by "O")
2.6 mm (electrical state modified by "F")
4.3 mm (total stroke)
description of iso n°1 terminals
(13-14)NO
signaling unit head shape
round
bezel material
Chrome plated metal
electrical life
1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0, 5 conforming to EN/IEC 60947-5-1 appendix C
resistance to high pressure cleaning
7000000Pa at 55°C, distance: 0.1m
connection mode
Screw clamp terminals, <= 2 x 1.5mm² with cable end conforming to EN 60947-1
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN 60947-1
contact operation
Slow-action
type of lock
Key 455
contact material
Silver alloy (Ag/Ni)
mechanical endurance
300000 cycle
width (w)
40 mm
electrical reliability
Λ < 10exp(-6) at 5 V and 1 mA in healthy environment conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V and 5 mA in healthy environment conforming to EN/IEC 60947 -5-4
actuation force
44 N
control unit profile
Red punch Ø 40mm, unmarked
screw head shape
Transversal compatible with Phillips n° 1 screwdriver
Transversal compatible with pozidriv n°1 screwdriver
Perforated compatible with flat Ø 4 mm screwdriver
Perforated compatible with flat Ø 5.5 mm screwdriver
product presentation
Complete product
depth
104 mm
key withdrawal position
Between
positive aperture
With conforming to EN/IEC 60947-5-1 appendix K
use of contacts
Contacts standards
short circuit protection
10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
Environment
ip degree of protection
IP66 conforming to CEI 60529
IP67
IP69
IP69K
product certificates
DNV
CSA
LROS (Lloyds register of shipping)
listé UL
GL
BV
class of protection against electric shock
Class I conforming to IEC 60536
standards
EN/CEI 60947-5-4
JIS C8201-5-1
CEI 60364-5-53
EN/CEI 60204-1
UL 508
EN/CEI 60947-5-1
EN/CEI 60947-1
EN/CEI 60947-5-5
EN/ISO 13850
CSA C22.2 No 14
JIS C8201-1
shock resistance ik
IK03 conforming to IEC 50102
operating ambient air temperature
-40…70 °C
storage room temperature
-40…70 °C
mechanical shock resistance
30 gn (duration = 18 ms) for acceleration on 1/2 sinusoid conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for acceleration on 1/2 sinusoid conforming to IEC 60068-2-27
vibration resistance
5 gn (f= 2...500 Hz) conforming to IEC 60068-2-6
resistance to nema environment
NO 13
NO 4X
protective treatment
TH