Complementary
electrical insulation class
Class III conforming to EN/IEC 62052-11
equipment included
Remote display
Adapter for remote display
Mounting instructions Mounting
hardware
power quality analysis
compliance verification EN 50160
conforming to IEEE 519 harmonic limit
conforming to IEC 61000-4-30: class A compliance reporting
conforming to IEEE 519 compliance reporting
waveform capture
total demand distortion
total harmonic distortion
up to 63rd harmonic
up to the 127th harmonic with software
detection of the direction of disturbance
dip, swell and transient
half cycle data acquisition
detection of transients (20 µs)
[in] rated current
1 A
5 A
[un] rated nominal voltage
90...480 V CA 45…66 Hz +/- 10 %
90...120 V CA 400 Hz +/- 10 %
110...480 V CC +/- 15 %
application
Power monitoring
WAGES
metering Net metering
Medium voltage
High voltage
facility category
III
memory capacity
2 Go
Handle front plate colour
160 mm
accuracy class
Class 0.1S active energy conforming to IEC 62053-22
Class 0.1 active energy conforming to IEC 61557-12
Class 0.1 active energy conforming to ANSI C12.20
Class 0.5S reactive energy conforming to IEC 62053-24
Class 0.1 current conforming to IEC 61557-12
Class 0.1 voltage conforming to IEC 61557-12
Class 0.1 active power conforming to IEC 61557-12
Class 0.5 power factor conforming to IEC 61557-12
data logging
Time stamp Min/ max
number of instantaneous values
User-definable data logs
Continuous logging or snapshot
Trend/forecast
Event reports
Alarm logs
Configuration change
Power outage
User login/logout
Data reports
GPS synchronization
Event recording sequence
product weight
1,5 kg
measuring current
0,01…20 A
power consumed in va
80 VA at 480 V AC
type of measurement
Undervoltages and overvoltages
Current sags and swells
Voltage
Current
Frequency
Total active and reactive power Total
apparent
power Active and reactive power per phase
Apparent power per phase
Total power
factor Power factor per phase
Active and reactive
energy Apparent energy
Harmonic distortion (I THD &U THD)
communication gateway
Serial Ethernet
cybersecurity
Syslog protocol support
Robust security
logs Communication port hardening
Enable/disable communication ports
Hardware metrology lock
settings protection
Protected by sealable cover
width (w)
160 mm
network frequency
50 Hz
60 Hz
number of entries
8 numbers 30 V AC/60 V DC
number of outputs
4 logic
2 form C relay output
input type
voltage (impedance 5 MOhm)
5 external CT (impedance 0.3 mOhm)
frequency measurement range
20…450 Hz
measurement accuracy
Tension +/- 0.1 %
Courant +/- 0.1 %
communication port protocol
Modbus RTU at 2400…115200 bps - 2 wires
ION at 2400…115200 bps - 2 wires
DNP3 at 2400…115200 bps - 2 wires
Modbus TCP at 10/100 Mbit/s
ION TCP at 10/100 Mbit/s
DNP3 TCP at 10 /100 Mbit/s
IEC 61850
Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s
DHCP
DNS
DLMS
depth
135,3 mm
mounting bracket
DIN rail measuring device
Remote screen door circuit breaker
Network type
3P+N+T
support port de communication
2 RS485 removable screw terminal block
sampling rate
1024 samples/cycle
display resolution
800 x 480 pixels
port ethernet
10/100BASE-TX 2 RJ45
synchronization protocol
GPS
IRIG-B
NTP
SNTP
PTP
measuring voltage
57…400 V CA 42…69 Hz entre phase and neutre
100…690 V CA 42…69 Hz entre phases
type of display
Remote LCD display
Color touch screen
service ethernet
DHCP Client
Device Profile Web Services (DPWS)
Ring Management Protocol (RSTP)
FTP/HTTP/HTTPS
travel time
100 ms 6 cycles at 60 Hz 120 V CA typique
400 ms 24 cycles at 60 Hz 240 V CA typique
1200 ms 72 cycles at 60 Hz 480 V CA typique
insulation voltage
CAT III, 400...690 V conforming to EN 61010-1:ed. 3
CAT III, 347...600 V conforming to UL 61010-1:ed. 3
CAT III, 347...600 V conforming to CSA C22.2 No 61010-1:ed. 3
type of count
Demand current I1, I2, I3, I4, I5
Peak demand currents
Active (P), reactive (Q) and apparent (S) power requested
Peak power P, Q, S requested
Calculated active and reactive energy (+/- Wh, +/- VAR.h)
Environment
ip degree of protection
IP65 front:
IP30 rear:
operating altitude
0...3000 m
electromagnetic compatibility
EMC immunity conforming to IEC 62052-11
EMC immunity conforming to IEC 61326-1
EMC immunity conforming to IEC 61000-6-5
Electrostatic discharge immunity test conforming to IEC 6100-4-11 Radiated
field immunity conforming to IEC 61000-4-3
Immunity to fast transients conforming to IEC 61000-4-4
Immunity to overvoltages conforming to IEC 61000-4-5
Immunity to conducted disturbances conforming to IEC 61000-4- 6
Immunity to mains frequency magnetic fields conforming to IEC 61000-4-8
Immunity to conducted disturbances - test level: 2...150 kHz conforming to CLC/TR 50579
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Impulse wave immunity conforming to IEC 61000-4-12
Conducted and radiated emissions conforming to EN 55011 Conducted
emissions and radiated emissions class B conforming to EN 55032 Conducted
and radiated emissions class B conforming to FCC Part 15 Conducted and radiated
emissions class B conforming to ICES-003
Resistance conforming to ANSI C37.90.1
Resistance conforming to IEEE C37.90.1
standards
ANSI C12.20
ANSI C37.90.1
IEC 61000-4-15
CEI 61000-4-30
CEI 61010-1
CEI 61326-1
CEI 61557-12
CEI 61850
CEI 62052-11
CEI 62052-31
CEI 62053-22
CEI 62053-23
CEI 62053-24
CEI 62586
UL 61010-1
quality labels
ISO 9001
ISO 14000
relative humidity
5…95%
operating temperature
-25…70 °C
storage room temperature