Main
product range
TeSys D
Range
TeSys
[uc] control circuit voltage
24 V CC
job category
AC-1
name of the device
LP1D
switch application
Resistive load (AC-1)
type of product or equipment
contactor
[ui] rated insulation voltage
Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
control circuit type
CC CC standard
composition of the power pole contacts
2F+2O
average impedance
1.5 mOhm - Ith 80 A 50 Hz for power circuit
Complementary
[ie] rated operational current
80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
[ue] rated operational voltage
Power circuit: <= 1000 V AC 25...400 Hz
compatibility code
LP1D
[ics] rated service breaking capacity
1000 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current
110 A at <40°C - 10 min for
260 A power circuit at <40°C - 1 min for
520 A power circuit at <40°C - 10 s for
900 A power circuit at <40°C - 1s for power circuit
[ith] conventional thermal current
80 A at <60 °C) for power circuit
caliber of the fuse to be associated
125 A gG at <= 690 V type 1 coordination for power circuit
125 A gG at <= 690 V type 2 coordination for power circuit
average consumption on hold in w
22W at 20°C
Handle front plate colour
127 mm
tightening torque
Power circuit: 8 Nm - on screw clamp terminals - cable 25...35 mm² hexagonal screw head 4 mm
Remote control: 1.7 Nm - on screw clamp terminals - with flat screwdriver Ø 6 mm
Remote control: 1.7 Nm - on screw-clamp terminals - with No. 2 Phillips screwdriver
Power circuit: 5 Nm - on screw-clamp terminals - cable 1…25 mm² hexagonal screw head 4 mm
Remote control: 1.7 Nm - on screw terminals -caliper - with pozidriv n°2 screwdriver
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
product weight
2,22 kg
contact compatibility
M3
electrical life
1.5 Mcycles 80 A AC-1 at Ue <= 440 V
connection mode
Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible without cable end
Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: flexible without cable
end power: screw clamp terminals 1 2.5…25 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 2 2.5…10 mm² - cable stiffness: flexible with cable end
Power circuit: screw clamp terminals 1 2.5…25 mm² - cable stiffness: rigid
Power circuit: screw clamp terminals 2 2.5…16 mm² - cable stiffness: rigid
Remote control: screw clamp terminals 1 1… 4 mm² - cable stiffness: flexible without cable end
Remote control: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end
Remote control: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end
Remote control: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Remote control: screw clamp terminals 1 1…4 mm² - cable stiffness: rigid
Remote control: screw clamp terminals 2 1…4 mm² - cable stiffness: rigid
control circuit voltage range
0.1...0.3 Uc -40...55 °C DC level loss
0.85...1.1 Uc -40...55 °C DC operational
mechanical endurance
10 Mcycles
width (w)
85 mm
mechanical robustness
Contactor open shocks (8 Gn for 11 ms)
Contactor closed shocks (10 Gn for 11 ms)
Contactor open vibrations (2 Gn, 5 to 300 Hz)
Contactor closed vibrations (3 Gn, 5 to 300 Hz)
Flame retardance
V1 conforming to UL 94
time constant
75 ms
rated rms inrush power
1000 A at 440 V for power circuit conforming to IEC 60947
depth
182 mm
mounting bracket
Platine
Rail
frequency
Without
maximum inrush power in w
22W (at 20°C)
operating time
4…19 ms opening
12…26 ms closing
power loss per pole
9,6 W AC-1
security reliability level
B10d = 1369863 contactor cycle with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 contactor cycle with mechanical load conforming to EN/ISO 13849-1
max command speed
3600 cycles/h at <60°C
coil technology
Built-in bi-directional peak limit diode suppressor
Poles description
4P
Environment
degree of pollution
3
ip degree of protection
IP20 front face conforming to IEC 60529
operating altitude
0...3000 m
product certificates
UL
CSA
CCC
EAC
UKCA
CB
DNV-GL
RINA
BV
LROS (Lloyds register of shipping)
ambient air temperature for operation
-40…60 °C
60…70 °C with current reduction
overvoltage category
III
standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
CEI 60947-4-1
CEI 60947-5-1
UL 508
fire resistance
850 °C conforming to IEC 60695-2-1