Default
Seeria
TeSyS Deca kontaktorid
Main
Range
TeSys
[uc] control circuit voltage
230 V AC 50/60Hz
job category
AC-1
AND-3
name of the device
LC2D
switch application
Resistive load (AC-1)
Motor control (AC-3)
type of product or equipment
Reversing contactor
Product Name
TeSys D
[ui] rated insulation voltage
Power circuit: 1000 V conforming to IEC 60947-4-1
Signaling circuit: 690 V conforming to IEC 60947-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signaling circuit: 600 V CSA Certified
Signaling Circuit: 600V UL Certified
control circuit type
AC at 50/60 Hz
engine power hp
20 hp at 200/208 VAC 60 Hz for 3 phase motors
7.5 hp at 115 VAC 60 Hz for single phase motors
15 hp at 230/240 VAC 60 Hz for single phase motors
25 hp at 230/240 VAC 60 Hz for 3-phase motors
60 hp at 460/480 V AC 60 Hz for 3-phase motors
60 hp at 575/600 V AC 60 Hz for 3-phase motors
composition of the power pole contacts
3F
motor power kW
45 kW at 415...440 V AC 50 Hz (AC-3)
55 kW at 500 V AC 50 Hz (AC-3)
45 kW at 660...690 V AC 50 Hz (AC-3)
45 kW at 1000 V CA 50 Hz (AC-3)
25 kW at 220...230 V CA 50 Hz (AC-3)
45 kW at 380...400 V CA 50 Hz (AC-3)
average impedance
0.8 mOhm - Ith 125 A 50 Hz for power circuit
Complementary
[ie] rated operational current
125 A (at <60°C) at <= 690 V AC-1 for power circuit
95 A (at <60°C) at <= 440 V AC-3 for power circuit
95 A (at <60°C ) at <= 440 V AC-3e for power circuit
[ue] rated operational voltage
Power circuit: 1000 V AC 25...400 Hz
Power circuit: <= 300 V DC
[ics] rated service breaking capacity
1100 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current
135 A at <40°C - 10 min for
400 A power circuit at <40°C - 1 min for
800 A power circuit at <40°C - 10 s for
1100 A power circuit at <40°C - 1s for
100 A power circuit - 1s for
120 A signaling circuit - 500 ms for
140 A signaling circuit - 100 ms for signaling circuit
[ith] conventional thermal current
10 A at <60°C) for signaling circuit
125 A at <60°C) for power circuit
caliber of the fuse to be associated
10 A gG for signaling circuit conforming to IEC 60947-5-1
200 A gG at <= 690 V type 1 coordination for power circuit
160 A gG at <= 690 V type 2 coordination for power circuit
Handle front plate colour
127 mm
tightening torque
Remote control: 1.2 Nm - on screw-clamp terminals - with flat screwdriver Ø 6 mm
Remote control: 1.2 Nm - on screw-clamp terminals - with Phillips No. 2 screwdriver
Power circuit: 12 Nm - on connector - with flat screwdriver Ø 6 to Ø 8 mm
Power circuit: 12 Nm - on hexagonal connector with 4 mm screw head
Remote control: 1.2 Nm - on screw clamp terminals - with pozidriv n°2 screwdriver
[uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947
auxiliary contacts
2 "O" + 2 "F"
average fuel consumption when going
26 VA 60 Hz cos phi 0.3 (at 20°C)
26 VA 50 Hz cos phi 0.3 (at 20°C)
minimum switching current
5 mA for signaling circuit
product weight
3,2 kg
type of auxiliary contacts
mechanically linked type 1 NC + 1 NO conforming to IEC 60947-5-1
1 NC mirror contact type conforming to IEC 60947-4-1
electrical life
1,2 Mcycles 95 A AC-3
1,3 Mcycles 125 A AC-1
1,2 Mcycles 95 A AC-3e
connection mode
Remote control: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end
Remote control: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end
Remote control: screw clamp terminals 2 cable( s) 1…2.5 mm²flexible with cable end
Remote control: screw clamp terminals 1 cable(s) 1…4 mm²rigid
Remote control: screw clamp terminals 2 cable(s) 1…4 mm²rigid
Remote control: screw terminals- clamp 1 cable(s) 1...2.5 mm²flexible with cable end
Power circuit: connector 1 cable(s) 4...50 mm²flexible without cable end
Power circuit: connector 2 cable(s) 4...25 mm²flexible without end cable
Power circuit: connector 1 cable(s) 4...50 mm²flexible with cable end
Power circuit: connector 2 cable(s) 4...16 mm²flexible with cable end
Power circuit: connector 1 cable(s) 4...50 mm²rigid
Power circuit: connector 2 cable(s) 4...25 mm² rigid
type of lock
Mechanical
control circuit voltage range
0.3...0.6 Uc -40...70 °C dropout AC 50/60 Hz
0.8...1.1 Uc -40...55 °C operational AC 50 Hz
0.85...1.1 Uc -40 …55 °C operational AC 60 Hz
1...1.1 Uc 55…70 °C operational AC 50/60 Hz
mechanical endurance
4 Mcycles
width (w)
182 mm
mechanical robustness
Contactor open vibrations: 2 Gn, 5 to 300 Hz
Contactor open shocks: 8 Gn for 11 ms
Contactor closed vibrations: 3 Gn, 5 to 300 Hz
Contactor closed shocks: 10 Gn for 11 ms
Flame retardance
V1 conforming to UL 94
product presentation
Pre-assembled with reversing busbars
rated rms inrush power
140 A AC for signaling circuit conforming to IEC 60947-5-1
250 A DC for signaling circuit conforming to IEC 60947-5-1
1100 A at 440 V for power circuit conforming to IEC 60947
depth
158 mm
mounting bracket
Rail
Platine
frequency
With
signaling circuit frequency
25 to 400 Hz
calling power goes
245 VA 60 Hz cos phi 0.75 (at 20°C)
245 VA 50 Hz cos phi 0.75 (at 20°C)
operating time
20…35 ms closing
6…20 ms opening
power loss per pole
12,5 W AC-1
7,2 W AC-3
7,2 W AC-3e
security reliability level
B10d = 1.3 Mcycles contactor with rated load conforming to EN/ISO 13849-1
B10d = 20 Mcycles contactor with mechanical load conforming to EN/ISO 13849-1
max command speed
3600 cycles/h at <60°C
minimum switching voltage
17 V for signaling circuit
non-overlap time
1.5 ms on de-
energization between NC and NO contact 1.5 ms on excitation between NC and NO contact
coil technology
Without integrated interference suppression module
Poles description
3P
Environment
degree of pollution
3
ip degree of protection
IP20 front face conforming to IEC 60529
operating altitude
0...3000 m
product certificates
UL
CSA
RINA
GOST
CCC
DNV
LROS (Lloyds register of shipping)
GL
BV
UKCA
overvoltage category
III
standards
EN/CEI 60947-1
EN/CEI 60947-4-1
EN/CEI 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947 -5-1
GB/T 14048.4
fire resistance
850 °C conforming to IEC 60695-2-1
thermal dissipation
6…10 W at 50/60 Hz
operating temperature
-40…60 °C
60…70 °C with current reduction
storage room temperature
-60…80 °C
climatic resistance
conform to IACS E10
protective treatment
TH conforming to IEC 60068-2-30
insulation resistance
> 10 MΩ for signaling circuit