Default
Seeria
TeSyS Deca kontaktorid
Main
Range
TeSys
TeSys Deca
[uc] control circuit voltage
24 V CC
job category
AC-1
AND-3
name of the device
LC2D
switch application
Resistive load (AC-1)
Motor control (AC-3)
type of product or equipment
Reversing contactor
Product Name
TeSys D
TeSys Deca
[ui] rated insulation voltage
Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signaling circuit: 690 V conforming to IEC 60947-1
Signaling circuit: 600 V CSA Certified
Signaling Circuit: 600V UL Certified
control circuit type
CC standard
engine power hp
3 hp at 230/240 V AC 60 Hz for single-phase motors
5 hp at 200/208 V AC 60 Hz for 3-phase motors
2 hp at 115 V AC 60 Hz for single-phase motors
7.5 hp at 230/240 V AC 60 Hz for 3-phase motors
15 hp at 460/480 V AC 60 Hz for 3-phase motors
20 hp at 575/600 V AC 60 Hz for 3-phase motors
composition of the power pole contacts
3F
motor power kW
5,5 kW at 220...230 V AC 50 Hz
11 kW at 380...400 V AC 50 Hz
11 kW at 415...440 V AC 50 Hz
15 kW at 500 V AC 50 Hz
15 kW at 660 ...690 V AC 50 Hz
average impedance
2 mOhm - Ith 40 A 50 Hz for power circuit
Complementary
[ie] rated operational current
25 A (at <60°C) at <= 440 V AC AC-3 for power circuit
40 A (at <60°C) at <= 440 V AC AC-1 for power circuit
[ue] rated operational voltage
Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
[ics] rated service breaking capacity
450 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current
50 A at <40°C - 10 min for
120 A power circuit at <40°C - 1 min for
240 A power circuit at <40°C - 10 s for
380 A power circuit at <40°C - 1s for
100 A power circuit - 1s for
120 A signaling circuit - 500 ms for
140 A signaling circuit - 100 ms for signaling circuit
[ith] conventional thermal current
10 A at <60°C) for signaling circuit
40 A at <60°C) for power circuit
caliber of the fuse to be associated
10 A gG for signaling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V type 1 coordination for power circuit
40 A gG at <= 690 V type 2 coordination for power circuit
average consumption on hold in w
5.4W at 20°C
Handle front plate colour
85 mm
tightening torque
Remote control: 1.7 Nm - on screw-clamp terminals - with flat screwdriver Ø 6 mm
Remote control: 1.7 Nm - on screw-clamp terminals - with Phillips No. 2 screwdriver
Power circuit: 2.5 Nm - on screw-clamp terminals - with flat screwdriver Ø 6 mm
Power circuit: 2.5 Nm - on screw-clamp terminals - with Phillips n° 2 screwdriver
Remote control: 1.7 Nm - on screw-clamp terminals - with n°2 pozidriv screwdriver Power
circuit: 2.5 Nm - on screw clamp terminals - with n°2 pozidriv screwdriver
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
auxiliary contacts
1 "O" + 1 "F"
minimum switching current
5 mA for signaling circuit
product weight
1,117 kg
type of auxiliary contacts
mechanically linked type 1 NC + 1 NO conforming to IEC 60947-5-1
1 NC mirror contact type conforming to IEC 60947-4-1
electrical life
1.65 Mcycles 25 A AC-3 at Ue <= 440 V
1.4 Mcycles 40 A AC-1 at Ue <= 440 V
connection mode
Remote control: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end
Remote control: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end
Remote control: screw clamp terminals 1 cable( s) 1…4 mm²flexible with cable end
Remote control: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Remote control: screw clamp terminals 1 cable(s) 1…4 mm²rigid
Remote control: screw clamp terminals 2 cable(s) 1…4 mm²rigid
Power circuit : screw clamp terminals 1 cable(s) 2.5…10 mm²flexible without cable end
Power circuit : screw clamp terminals 2 cable( s) 2.5...10 mm²flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 1...10 mm²flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1.5...6 mm²flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1.5...10 mm²rigid
Power circuit : screw clamp terminals 2 cable(s) 2.5...10 mm²rigid
type of lock
Mechanical
control circuit voltage range
0.1 to 0.25 Uc -40…70 °C DC level drop
0.7 to 1.25 Uc -40…60 °C DC operational
1...1.25 Uc 60…70 °C DC operational
mechanical endurance
30 Mcycles
width (w)
90 mm
mechanical robustness
Contactor open vibrations: 2 Gn, 5 to 300 Hz
Contactor closed vibrations: 4 Gn, 5 to 300 Hz
Contactor closed shocks: 15 Gn for 11 ms
Contactor open shocks: 8 Gn for 11 ms
Flame retardance
V1 conforming to UL 94
product presentation
Pre-assembled with reversing busbars
time constant
28 ms
rated rms inrush power
140 A AC for signaling circuit conforming to IEC 60947-5-1
250 A DC for signaling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947
depth
101 mm
mounting bracket
Platine
Rail
frequency
With
maximum inrush power in w
5.4W (at 20°C)
signaling circuit frequency
25 to 400 Hz
operating time
53.55…72.45 ms closing
16…24 ms opening
power loss per pole
1,25 W AC-3
3,2 W AC-1
security reliability level
B10d = 1369863 contactor cycle with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 contactor cycle with mechanical load conforming to EN/ISO 13849-1
max command speed
3600 cycles/h at <60°C
minimum switching voltage
17 V for signaling circuit
non-overlap time
1.5 ms on de-
energization between NC and NO contact 1.5 ms on excitation between NC and NO contact
coil technology
Built-in bi-directional peak limit diode suppressor
Poles description
3P
Environment
degree of pollution
3
ip degree of protection
IP20 front face conforming to IEC 60529
operating altitude
0...3000 m
product certificates
DNV
CSA
CCC
UL
GL
LROS (Lloyds register of shipping)
BV
RINA
GOST
UKCA
overvoltage category
III
standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
CEI 60947-4-1
CEI 60947-5-1
UL 508
CEI 60335-1
fire resistance
850 °C conforming to IEC 60695-2-1
operating temperature
-40…60 °C
60…70 °C with current reduction
storage room temperature
-60…80 °C
climatic resistance
conforming to IACS E10
conforming to IEC 60947-1 Annex Q category D
protective treatment
TH conforming to IEC 60068-2-30
insulation resistance
> 10 MΩ for signaling circuit