LC2D12F7 – Schneider Electric

EAN: 3389110385786
70,67 € KM-ta
87,63 € KM-ga
TeSys LC2D - pöördkontaktor - 3P - AC-3 440V - 12A - 110Vac mähis. - Schneider Electric
87,63 €
SPETSIFIKATSIOONID
Default
Seeria TeSyS Deca kontaktorid
Main
Range TeSys
TeSys Deca
[uc] control circuit voltage 110 V AC 50/60 Hz
job category AC-3
AC-1
name of the device LC2D
switch application Resistive load (AC-1)
Motor control (AC-3)
type of product or equipment Reversing contactor
Product Name TeSys D
TeSys Deca
[ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signaling circuit: 690 V conforming to IEC 60947-1
Signaling circuit: 600 V CSA Certified
Signaling Circuit: 600V UL Certified
control circuit type AC at 50/60 Hz
engine power hp 1 hp at 115 V AC 60 Hz for single phase motors
2 hp at 230/240 V AC 60 Hz for single phase motors
3 hp at 200/208 V AC 60 Hz for 3 phase motors
3 hp at 230/240 V AC 60 Hz for 3 motor phases
7.5 hp at 460/480 V AC 60 Hz for 3 motor phases
10 hp at 575/600 V AC 60 Hz for 3 motor phases
composition of the power pole contacts 3F
motor power kW 3 kW at 220...230 V AC 50 Hz
5.5 kW at 380...400 V AC 50 Hz
5.5 kW at 415...440 V AC 50 Hz
7.5 kW at 500 V AC 50 Hz
7,5 kW at 660...690 V AC 50 Hz
average impedance 2.5 mOhm - Ith 25 A 50 Hz for power circuit
Complementary
[ie] rated operational current 25 A (at <60°C) at <= 440 V AC AC-1 for power circuit
12 A (at <60°C) at <= 440 V AC AC-3 for power circuit
[ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC
[ics] rated service breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current 30 A at <40°C - 10 min for
61 A power circuit at <40°C - 1 min for
105 A power circuit at <40°C - 10 s for
210 A power circuit at <40°C - 1s for
100 A power circuit - 1s for
120 A signaling circuit - 500 ms for
140 A signaling circuit - 100 ms for signaling circuit
[ith] conventional thermal current 10 A at <60°C) for signaling circuit
25 A at <60°C) for power circuit
caliber of the fuse to be associated 10 A gG for signaling circuit conforming to IEC 60947-5-1
40 A gG at <= 690 V type 1 coordination for power circuit
25 A gG at <= 690 V type 2 coordination for power circuit
Handle front plate colour 77 mm
tightening torque Power circuit: 1.7 Nm - on screw-clamp terminals - with Ø 6 mm flat screwdriver
Power circuit: 1.7 Nm - on screw-clamp terminals - with Phillips No. 2 screwdriver
Remote control: 1.7 Nm - on screw-clamp terminals - with flat screwdriver Ø 6 mm
Remote control: 1.7 Nm - on screw-clamp terminals - with Phillips No. 2 screwdriver
Remote control: 1.7 Nm - on screw-clamp terminals - with n°2 pozidriv screwdriver Power
circuit: 2.5 Nm - on screw clamp terminals - with n°2 pozidriv screwdriver
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
auxiliary contacts 1 "O" + 1 "F"
average fuel consumption when going 7.5 VA 60 Hz cos phi 0.3 (at 20°C)
7 VA 50 Hz cos phi 0.3 (at 20°C)
minimum switching current 5 mA for signaling circuit
product weight 0,697 kg
type of auxiliary contacts mechanically linked type 1 NC + 1 NO conforming to IEC 60947-5-1
1 NC mirror contact type conforming to IEC 60947-4-1
electrical life 2 Mcycles 12 A AC-3 at Ue <= 440 V
0.8 Mcycles 25 A AC-1 at Ue <= 440 V
connection mode Power circuit: screw clamp terminals 1 cable(s) 1...4 mm² flexible without cable end
Power circuit: screw clamp terminals 2 cable(s) 1...4 mm² flexible without cable end Power circuit: screw clamp
terminals screw clamp 1 cable(s) 1...4 mm²flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 1...4 mm²rigid
Power circuit: screw clamp terminals 2 cable(s) 1...4 mm²rigid
Remote control: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable
end screw clamp 2 cable(s) 1...4 mm²flexible without cable end
Remote control: screw clamp terminals 1 cable(s) 1...4 mm² flexible with cable end
Remote control: screw clamp terminals 2 cable(s) 1...2.5 mm² flexible with cable end
Remote control: screw clamp terminals 1 cable(s) 1...4 mm²rigid
Remote control: screw clamp terminals 2 cable(s) 1...4 mm²rigid
type of lock Mechanical
control circuit voltage range 0.3...0.6 Uc -40...70 °C dropout AC 50/60 Hz
0.8...1.1 Uc -40...60 °C operational AC 50 Hz
0.85...1.1 Uc -40 …60 °C operational AC 60 Hz
1...1.1 Uc 60…70 °C operational AC 50/60 Hz
mechanical endurance 15 Mcycles
width (w) 90 mm
mechanical robustness Contactor open vibrations: 2 Gn, 5 to 300 Hz
Contactor closed vibrations: 4 Gn, 5 to 300 Hz
Contactor open shocks: 10 Gn for 11 ms
Contactor closed shocks: 15 Gn for 11 ms
Flame retardance V1 conforming to UL 94
product presentation Pre-assembled with reversing busbars
rated rms inrush power 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signaling circuit conforming to IEC 60947-5-1
250 A DC for signaling circuit conforming to IEC 60947-5-1
depth 86 mm
mounting bracket Rail
Platine
frequency With
signaling circuit frequency 25 to 400 Hz
calling power goes 70 VA 60 Hz cos phi 0.75 (at 20°C)
70 VA 50 Hz cos phi 0.75 (at 20°C)
operating time 12…22 ms closing
4…19 ms opening
power loss per pole 1,56 W AC-1
0,36 W AC-3
security reliability level B10d = 1369863 contactor cycle with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 contactor cycle with mechanical load conforming to EN/ISO 13849-1
max command speed 3600 cycles/h at <60°C
minimum switching voltage 17 V for signaling circuit
non-overlap time 1.5 ms on de-
energization between NC and NO contact 1.5 ms on excitation between NC and NO contact
coil technology Without integrated interference suppression module
Poles description 3P
Environment
degree of pollution 3
ip degree of protection IP20 front face conforming to IEC 60529
operating altitude 0...3000 m
product certificates DNV
CSA
CCC
UL
GL
LROS (Lloyds register of shipping)
BV
RINA
GOST
UKCA
overvoltage category III
standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
CEI 60947-4-1
CEI 60947-5-1
UL 508
CEI 60335-1
fire resistance 850 °C conforming to IEC 60695-2-1
thermal dissipation 2…3 W at 50/60 Hz
operating temperature -40…60 °C
60…70 °C with current reduction
storage room temperature -60…80 °C
climatic resistance conforming to IACS E10
conforming to IEC 60947-1 Annex Q category D
protective treatment TH conforming to IEC 60068-2-30
insulation resistance > 10 MΩ for signaling circuit
KKK ja hinna lisateave

Võta meiega ühendust

Professionaalne elektriseadmete müük Eestis, Lätis, Leedus ja Soomes. Sertifitseeritud madalpinge komponendid, kaitselülitid, kontaktorid ja tööstusautomaatika lahendused. Sama päeva hinnapakkumised ja kiire tarne Baltikumis ja Soomes

Baltelec
+372 5326 4976

E–R 9:00–17:00

info@baltelec.ee

Vastame 2 tunni jooksul

Schneider Electric LC2D12F7 on toode kategooriast Tööstuslikud kontaktorid, mis on mõeldud professionaalidele. BaltElec tegeleb hulgimüügi ja toodete levitamisega Eestis, Lätis, Leedus ja Soomes.

  • Autentne Schneider Electric toode, vastavusdokumendid päringu alusel.
  • Projektihind – küsi pakkumist suuremate koguste jaoks (võimalik, et sätestame MOQ).
  • Tõhus ja kiire logistika Baltikumis ning Soomes; koostöö tunnustatud kulleritega.
  • Tehniline tugi ja nõustamine valikul vastavalt Sinu rakendusele.

Hinnainfo: Küsi projektipakkumist. Hind sõltub kogusest, tarne- ja maksetingimustest.

KKK tootele LC2D12F7 - Schneider Electric

Hiljuti vaadatud
LC2D12F7 - Schneider Electric
TeSys LC2D - pöördkontaktor - 3P - AC-3 440V - 12A - 110Vac mähis.
70,67 € KM-ta
87,63 € KM-ga
Tellimisel