Default
Seeria
TeSyS Deca kontaktorid
Main
product range
TeSys D
Range
TeSys
[uc] control circuit voltage
230 V AC 50/60Hz
job category
AC-1
AC-4
AC-3
AC-3e
name of the device
LC1D
switch application
Motor control (AC-3)
Resistive load (AC-1)
type of product or equipment
contactor
[ui] rated insulation voltage
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
Signaling circuit: 690 V conforming to IEC 60947-1
Signaling circuit: 600 V CSA Certified
Signaling Circuit: 600V UL Certified
control circuit type
AC at 50/60 Hz typical
engine power hp
30 hp at 200/208 V AC 50/60 Hz for 3-phase motors
40 hp at 230/240 V AC 50/60 Hz for 3-phase motors
75 hp at 460/480 V AC 50/60 Hz for 3-phase
100 hp motors at 575/600 V AC 50/60 Hz for 3 motor phases
composition of the power pole contacts
3F
motor power kW
30 kW at 220...230 V AC 50/60 Hz (AC-3)
55 kW at 380...400 V AC 50/60 Hz (AC-3)
59 kW at 415...440 V CA 50/ 60 Hz (AC-3)
75 kW at 500 V AC 50/60 Hz (AC-3)
80 kW at 660...690 V AC 50/60 Hz (AC-3)
65 kW at 1000 V CA 50/60 Hz (AC-3)
18,5 kW à 400 V AC 50/60 Hz (AC-4)
30 kW à 220...230 V AC 50/60 Hz (AC-3e)
55 kW à 380...400 V CA 50/60 Hz (AC-3e)
59 kW à 415...440 V CA 50/60 Hz (AC-3e)
75 kW à 500 V CA 50/60 Hz (AC-3e)
80 kW à 660. ..690 V AC 50/60 Hz (AC-3e)
65 kW at 1000 V AC 50/60 Hz (AC-3e)
average impedance
0.6 mOhm - Ith 200 A 50 Hz for power circuit
Complementary
[ie] rated operational current
200 A (at <60°C) at <= 440 V AC AC-1 for power circuit
115 A (at <60°C) at <= 440 V AC AC-3 for power circuit
115 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
[ue] rated operational voltage
Power circuit: <= 1000 V AC 25...400 Hz
Power circuit: <= 300 V DC
compatibility code
LC1D
[ics] rated service breaking capacity
1100 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current
250 A at <40°C - 10 min for
550 A power circuit at <40°C - 1 min for
950 A power circuit at <40°C - 10 s for
1100 A power circuit at <40°C - 1s for
100 A power circuit - 1s for
120 A signaling circuit - 500 ms for
140 A signaling circuit - 100 ms for signaling circuit
[ith] conventional thermal current
200 A at <60 °C) for power circuit
caliber of the fuse to be associated
250 A gG at <= 690 V type 1 coordination for power circuit
200 A gG at <= 690 V type 2 coordination for power circuit
10 A gG for signaling circuit
Handle front plate colour
158 mm
tightening torque
Remote control: 1.2 Nm - on screw-clamp terminals - with flat screwdriver Ø 6 mm
Remote control: 1.2 Nm - on screw-clamp terminals - with Phillips No. 2 screwdriver
Power circuit: 12 Nm - on connector hexagonal screw head 4 mm
Remote control: 1.2 Nm - on screw clamp terminals - with pozidriv n°2 screwdriver
[uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947
auxiliary contacts
1 "O" + 1 "F"
average fuel consumption when going
2…18 VA 60 Hz cos phi 0.3 (at 20 °C)
2…18 VA 50 Hz cos phi 0.3 (at 20 °C)
minimum switching current
5 mA for signaling circuit
product weight
2,5 kg
type of auxiliary contacts
mechanically linked type 1 NC + 1 NO conforming to IEC 60947-5-1
1 NC mirror contact type conforming to IEC 60947-4-1
contact compatibility
M13
electrical life
0.8 Mcycles 200 A AC-1 at Ue <= 440 V
0.95 Mcycles 115 A AC-3 at Ue <= 440 V
0.95 Mcycles 115 A AC-3e at Ue <= 440 V
connection mode
Remote control: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end
Remote control: screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable end
Remote control: screw terminal blocks- clamp 1 1…2.5 mm² - cable stiffness: flexible without cable end
Remote control: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end
Remote control: screw clamp terminals 1 1…2, 5 mm² - cable stiffness: solid without cable end
Remote control: screw clamp terminals 2 1...2.5 mm² - cable stiffness: solid without cable end
Power circuit: connector 1 10...120 mm² - cable stiffness: flexible without cable end
Power circuit: connector 2 10…50 mm² - cable stiffness: flexible without cable end
Power circuit: connector 1 10…120 mm² - cable stiffness: flexible with ferrule
Power circuit: connector 2 10…50 mm² - cable stiffness: flexible with ferrule
Power circuit: connector 1 10…120 mm² - cable stiffness : rigid without cable end
Power circuit: connector 2 10…50 mm² - cable stiffness: rigid without cable end
control circuit voltage range
0.3...0.5 Uc -40...70 °C dropout AC 50/60 Hz
0.8...1.15 Uc -40...55 °C operational AC 50/60 Hz
1...1.15 Uc 55…70 °C operational AC 50/60 Hz
mechanical endurance
8 Mcycles
width (w)
120 mm
mechanical robustness
Open contactor vibrations (2 Gn, 5 to 300 Hz)
Closed contactor vibrations (4 Gn, 5 to 300 Hz)
Closed contactor shocks (15 Gn for 11 ms)
Open contactor shocks (6 Gn for 11 ms)
Flame retardance
V1 conforming to UL 94
rated rms inrush power
1260 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signaling circuit conforming to IEC 60947-5-1
250 A DC for signaling circuit conforming to IEC 60947-5-1
depth
136 mm
mounting bracket
Rail
Platine
frequency
With
signaling circuit frequency
25 to 400 Hz
calling power goes
280…350 VA 60 Hz cos phi 0.8 (at 20 °C)
280…350 VA 50 Hz cos phi 0.8 (at 20 °C)
operating time
6…20 ms opening
20…50 ms closing
power loss per pole
24 W AC-1
7,9 W AC-3
7,9 W AC-3e
security reliability level
B10d = 1369863 contactor cycle with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 contactor cycle with mechanical load conforming to EN/ISO 13849-1
max command speed
2400 cycles/h at <60°C
minimum switching voltage
17 V for signaling circuit
non-overlap time
1.5 ms on de-
energization between NC and NO contact 1.5 ms on excitation between NC and NO contact
coil technology
Built-in bi-directional peak limit diode suppressor
Poles description
3P
Environment
degree of pollution
3
ip degree of protection
IP20 front face conforming to IEC 60529
operating altitude
0...3000 m
product certificates
LROS (Lloyds register of shipping)
RINA
DNV
GOST
BV
GL
CCC
CSA
UL
UKCA
CE
ambient air temperature for operation
-40…60 °C
60…70 °C with current reduction
overvoltage category
III
standards
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
CEI 60947-4-1
CEI 60947-5-1
UL 508
fire resistance
850 °C conforming to IEC 60695-2-1
thermal dissipation
3…8 W at 50/60 Hz
climatic resistance
conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat
protective treatment
TH conforming to IEC 60068-2-30
insulation resistance
> 10 MΩ for signaling circuit