Kõik kategooriad
Võrdle Ostukorv
STBART0200K - Standardne analoogsisendi komplekt STB 2 I 15 bitti + märk - Schneider Electric - Standardne analoogsisendi komplekt STB 2 I 15 bitti + märk - Schneider Electric - 0
STBART0200K - Standardne analoogsisendi komplekt STB 2 I 15 bitti + märk - Schneider Electric - Standardne analoogsisendi komplekt STB 2 I 15 bitti + märk - Schneider Electric - 0
Tellimisel

STBART0200K – Schneider Electric

235,73 € KM-ta
292,30 € KM-ga
Standardne analoogsisendi komplekt STB 2 I 15 bitti + märk - Schneider Electric
292,30 €
SPETSIFIKATSIOONID
Default
Seeria Advantys STB & ETB & X80
Main
Analogue input resolution 15 bits + sign
type of filter Single low pass input filter 25 Hz
Complementary
Absolute accuracy error +/- 0.1 % of full scale 25 °C internal
+/- 0.15 % of full scale 25 °C external
absolute maximum input +/- 7.5 V DC
product compatibility Mounting base STBXBA1000
Power distribution module STBPDT3100/3105
Kit composition STBART0200 module
STBXTS1100, 6-terminal screw type connector
STBXBA1000 base
STBXTS2100, 6-terminal spring clamp connector
Product certifications UL
FM Class 1 Division 2
CSA
ATEX Cat 3G
C-Tick
data formats EN 61131-2
IEC 61131-2
Product or component type Standard analog input kit
[us] rated supply voltage 24 V DC
Current consumption 30 mA at 5 V DC for logic bus
marking CE
Analogue input number 2
Analogue input type Voltage +/- 80 mV
Temperature probe -100...+260 °C Cu 10 2, 3 or 4 wires IEC
Temperature probe -100...+450 °C Pt 100 2, 3 or 4 wires US/JIS
Temperature probe -100...+450 °C Pt 1000 2, 3 or 4 wires US/JIS
Temperature probe -200...+850 °C Pt 100 2, 3 or 4 wires IEC
Temperature probe -200...+850 °C Pt 1000 2, 3 or 4 wires IEC
Temperature probe -60...+180 °C Ni 100 2, 3 or 4 wires IEC
Temperature probe -60...+180 °C Ni 1000 2, 3 or 4 wires IEC
Thermocouple +130...+1820 °C thermocouple B
Thermocouple -200...+760 °C thermocouple J
Thermocouple -270...+1000 °C thermocouple E
Thermocouple -270...+1370 °C thermocouple K
Thermocouple -270...+400 °C thermocouple T
Thermocouple -50...+1665 °C thermocouple R
Thermocouple -50...+1665 °C thermocouple S
Cold swapping Yes
addressing requirement 1 word for cold-junction compensation
2 input words
Fallback status State 0 basic NIMs
User configurable standard NIMs
maximum wiring resistance 20 Ohm Cu 10 IEC/US/JIS 2 or 3 wires
20 Ohm Ni 100 IEC/US/JIS 2 or 3 wires
20 Ohm Pt 100 IEC/US/JIS 2 or 3 wires
200 Ohm Ni 1000 IEC/US/JIS 2 or 3 wires
200 Ohm Pt 1000 IEC/US/JIS 2 or 3 wires
50 Ohm Cu 10 IEC/US/JIS 4 wires
50 Ohm Ni 100 IEC/US/JIS 4 wires
50 Ohm Pt 100 IEC/US/JIS 4 wires
500 Ohm Ni 1000 IEC/US/JIS 4 wires
500 Ohm Pt 1000 IEC/US/JIS 4 wires
Hot swapping fallback Yes for standard NIMs
measurement accuracy +/- 1 °C Ni 100 25 °C external
+/- 1 °C Ni 100 25 °C internal
+/- 1 °C Ni 1000 25 °C external
+/- 1 °C Ni 1000 25 °C internal
+/- 1 °C Pt 100 25 °C internal
+/- 1 °C Pt 1000 25 °C internal
+/- 1.75 °C thermocouple B with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple E with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple J with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple K with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple R with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple S with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple T with external cold-junction compensation 25 °C
+/- 2 °C Pt 100 25 °C external
+/- 2 °C Pt 1000 25 °C external
+/- 2.85 °C thermocouple B with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple E with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple J with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple K with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple R with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple S with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple T with external cold-junction compensation 60 °C
+/- 3.6 °C thermocouple R with internal cold-junction compensation 25 °C
+/- 4 °C Cu 10 25 °C external
+/- 4 °C Cu 10 25 °C internal
+/- 4 °C thermocouple K with internal cold-junction compensation 25 °C
+/- 4.1 °C thermocouple S with internal cold-junction compensation 25 °C
+/- 4.2 °C thermocouple R with internal cold-junction compensation 60 °C
+/- 4.4 °C thermocouple T with internal cold-junction compensation 25 °C
+/- 4.6 °C thermocouple B with internal cold-junction compensation 25 °C
+/- 4.6 °C thermocouple E with internal cold-junction compensation 25 °C
+/- 5 °C thermocouple S with internal cold-junction compensation 60 °C
+/- 5.1 °C thermocouple J with internal cold-junction compensation 25 °C
+/- 5.5 °C thermocouple K with internal cold-junction compensation 60 °C
+/- 6.4 °C thermocouple T with internal cold-junction compensation 60 °C
+/- 6.8 °C thermocouple B with internal cold-junction compensation 60 °C
+/- 6.8 °C thermocouple E with internal cold-junction compensation 60 °C
+/- 7 °C thermocouple J with internal cold-junction compensation 60 °C
input impedance 10 MOhm +/- 80 mV
Measurement resolution 0.01 mV voltage
0.1 °C or 0.1 °F temperature probe
0.1 °C or 0.1 °F thermocouple
Insulation between channels and logic bus 1500 V for 1 minute
Maximum supply current for sensors 100 mA per input channels
Pollution degree 2 conforming to IEC 60664-1
Shock resistance 30 gn for 11 ms conforming to IEC 88 reference 2-27
conversion time 150 ms voltage 60 Hz
170 ms voltage 50 Hz
180 ms temperature probe 60 Hz 2 or 4 wires
200 ms temperature probe 50 Hz 2 or 4 wires
210 ms thermocouple with internal cold-junction compensation 60 Hz
230 ms thermocouple with internal cold-junction compensation 50 Hz
300 ms temperature probe 60 Hz 3 wires
340 ms temperature probe 50 Hz 3 wires
360 ms thermocouple with external cold-junction compensation 60 Hz
400 ms thermocouple with external cold-junction compensation 50 Hz
Status led 1 LED (green) module status (RDY)
1 LED (red) module error (ERR)
Supply Power distribution module
Protection type Short-circuit protection
Environment
Ambient air temp for storage/transportation -40...185 °F without derating
ip degree of protection IP20 conforming to EN 61131-2 class 1
operating altitude <= 2000 m
Range of product Modicon STB distributed I/O solution
ambient air temperature for operation 32...140 °F without derating
overvoltage category II
relative humidity 95 % at 60 °C without condensation
vibration resistance +/-0.35 mm at 10…58 Hz
3 gn at 58…150 Hz on 35 x 7.5 mm symmetrical DIN rail
5 gn at 58…150 Hz on 35 x 15 mm symmetrical DIN rail
KKK ja hinna lisateave

Võta meiega ühendust

Professionaalne elektriseadmete müük Eestis, Lätis, Leedus ja Soomes. Sertifitseeritud madalpinge komponendid, kaitselülitid, kontaktorid ja tööstusautomaatika lahendused. Sama päeva hinnapakkumised ja kiire tarne Baltikumis ja Soomes

Baltelec
+372 5326 4976

E–R 9:00–17:00

info@baltelec.ee

Vastame 2 tunni jooksul

STBART0200K on toode kategooriast PLC, PAC ja pühendatud kontrollerid, mis on mõeldud professionaalidele. BaltElec tegeleb mahupõhise müügi ja toodete levitamisega Eestis, Lätis, Leedus ja Soomes.

  • Originaal Schneider Electric toode, sertifikaadid ja vastavusdokumendid saadaval.
  • Projektihind – küsi pakkumist suuremate koguste jaoks (võimalik, et sätestame MOQ).
  • Tõhus ja kiire logistika Baltikumis ning Soomes; koostöö tunnustatud kulleritega.
  • Tehniline tugi ja ettepanekud sobivuse kohta vastavalt Sinu rakendusele.

Hinnainfo: Küsi projektipakkumist. Hind sõltub kogusest, tarne- ja maksetingimustest.

KKK tootele STBART0200K - Schneider Electric

Hiljuti vaadatud
STBART0200K - Schneider Electric
Standardne analoogsisendi komplekt STB 2 I 15 bitti + märk
235,73 € KM-ta
292,30 € KM-ga
Tellimisel