Main
product range
Telemecanique XY2C cable emergency stop
[ithe] thermal current under enclosure
10 A
reliability data
B10d = 500000 value for a lifetime of 20 years limited by wear or contact conforming to IEC 60947-5-5
name of the device
XY2C
type of product or equipment
Rope emergency stop lock
[ui] rated insulation voltage
500 V (pollution degree 3) conforming to EN/IEC 60947-1
300 V conforming to UL 508
300 V conforming to CSA C22.2 No 14
security level
Up to PL = e with appropriate monitoring system and correct wiring conforming to EN/ISO 13849-1
Up to category 4 with appropriate monitoring system and correct wiring conforming to EN/ISO 13849-1
Up to SIL 3 with appropriate monitoring system and correct wiring conforming to EN/IEC 61508
reset
By pulling the button
Complementary
[ie] rated operational current
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
compatibility code
XY2CJ
contact description
2 "O"
number of cables
1
number of cable entries
1 tapped entry for PG13.5 cable gland
tightening torque
0,8…1,2 N.m
[uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-1
product weight
0,455 kg
description of iso n°1 terminals
(11-22)NC
(21-22)NC
marking
THIS
Housing colour
Rouge RAL 3000
connection mode
Screw clamp terminals, 1 x 0.5...2 x 1.5 mm²
contact operation
Slow-action
distance between cable supports
5 m
body material
the burdens
mechanical endurance
100000 cycle
Local signalling
color indicator
maximum trip cable length
20 m
head material
Polyamide
cover material
Galvanized steel
positive aperture
With conforming to EN/IEC 60947-5-1
trigger cable anchor point
Right or left side
maximum resistance between terminals
25 MΩ conforming to EN/IEC 60255-7 category 3
25 MΩ conforming to NF C 93-050 method A
short circuit protection
10 A cartridge fuse type gG conforming to EN/IEC 60269
Environment
ip degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
product certificates
UL category emergency stop devices NISD
CSA
CCC
EAC
operating ambient temperature
-25…70 °C
overvoltage category
Class I conforming to EN/IEC 61140
standards
EN/IEC 60947-5-1
CSA C22.2 No 14
UL 508
EN/IEC 60947-5-5
EN/ISO 13850
Machinery Directive 2006/42/EC
EN/IEC 60204-1
Work Equipment Directive 2009/104 / THIS
storage room temperature
-40…70 °C
mechanical shock resistance
50 gn 11 ms conforming to EN/IEC 60068-2-27
vibration resistance
10 gn (f= 10...150 Hz) conforming to EN/IEC 60068-2-6
protective treatment
TC