SPETSIFIKATSIOONID
Main
Safety module application For monitoring of single beam photo-electric sensor
Safety module name XPSCM
[ui] rated insulation voltage 300 V (pollution degree 2) conforming to DIN VDE 0110 parts 1 and 2
300 V (pollution degree 2) conforming to EN/IEC 60947-5-1
Complementary
[ics] rated service breaking capacity 20 mA at 24 V for solid state output
1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
Product or component type Safety module
[uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to DIN VDE 0110 parts 1 and 2
4 kV overvoltage category III conforming to EN/IEC 60947-5-1
[us] rated supply voltage 24 V DC - 20...20 %
Connections - terminals Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid or flexible without cable end
Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel
Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid without cable end
Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible without cable end
Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel
Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
Associated fuse rating 4 A gG for relay output conforming to DIN VDE 0660 part 200
4 A gG for relay output conforming to EN/IEC 60947-5-1
6 A fast blow for relay output conforming to DIN VDE 0660 part 200
6 A fast blow for relay output conforming to EN/IEC 60947-5-1
minimum output current 10 mA for relay output
output thermal current 5.6 A per relay
11 A maximum
Output type Relay 2 NO (13-14, 23-24), volt-free
Function of module Built-in muting
input current 200 mA for muting function
safety reliability data MTTFd = 16.6 years conforming to EN/ISO 13849-1
DC = 95.5 % conforming to EN/ISO 13849-1
PFH = 3.12E-7 1/h conforming to EN/IEC 61508
PFHd = 3.12E-7 1/h conforming to EN/IEC 62061
Local signalling 1 LED, function electronic internal fuse status
1 LED, function restarting
1 LED, function safety outputs closed
1 LED, function safety outputs open
1 incandescent lamp, function muting power consumption: 4…6.5 W
maximum line resistance 10 Ohm for sensor power supply
Maximum response time on input open 25 ms
Maximum supply current for sensors 200 mA
minimum output voltage 17 V for relay output
Muting maximum duration 60 s (- 10...30 %)
Number of inputs 2 (terminal(s) MA, MB) for muting function
4 (terminal(s) Z1, Z2, Z3, Z4) for sensor
Power consumption in w 15 W
input voltage 24 V DC for sensor
24 V DC (terminal(s) U+, U-) for muting function
Sensor power supply U+, U-: 24 V DC
Input compatibility XC limit switch for muting function
XU2M18PP340... for muting function
XU2S18PP340... (infrared) for sensor
XU9M18PP340... for muting function
Synchronisation time between inputs 3 s (+/- 20 %) for the activation of the MA/MB muting signal
Safety level Can reach category 2 with the appropriate control system and correctly wired conforming to EN/ISO 13849-1
Can reach SILCL 1 with the appropriate control system and correctly wired conforming to EN/IEC 62061
Can reach PL = c with the appropriate control system and correctly wired conforming to EN/ISO 13849-1
Protection type Electronic internal fuse
Environment
Ambient air temp for storage/transportation -25…85 °C
ip degree of protection IP20 (terminals) conforming to IEC 60529
IP40 (enclosure) conforming to IEC 60529
Range of product Telemecanique Safety light curtains XUSL
ambient air temperature for operation -10…55 °C
KKK ja hinna lisateave

Võta meiega ühendust

Professionaalne elektriseadmete müük Eestis, Lätis, Leedus ja Soomes. Sertifitseeritud madalpinge komponendid, kaitselülitid, kontaktorid ja tööstusautomaatika lahendused. Sama päeva hinnapakkumised ja kiire tarne Baltikumis ja Soomes

Baltelec
+372 5326 4976

E–R 9:00–17:00

info@baltelec.ee

Vastame 2 tunni jooksul

XPSCM1144P on lahendus kategooriast Preventa XCS, mis on mõeldud professionaalidele. BaltElec tegeleb hulgimüügi ja toodete levitamisega Eestis, Lätis, Leedus ja Soomes.

  • Originaal Schneider Electric toode, sertifikaadid ja vastavusdokumendid saadaval.
  • Projektihind – küsi pakkumist suuremate koguste jaoks (võimalik, et sätestame MOQ).
  • Tõhus ja kiire logistika Baltikumis ning Soomes; koostöö tunnustatud kulleritega.
  • Tehniline tugi ja nõustamine valikul vastavalt Sinu rakendusele.

Hind: Küsi eripakkumist. Hind sõltub kogusest, tarne- ja maksetingimustest.

KKK tootele XPSCM1144P - Schneider Electric

Hiljuti vaadatud
XPSCM1144P - Schneider Electric
Moodul XPSCM üksikkiirgusega fotoelektrilised andurid 24 V DC
273,81 € KM-ta
339,52 € KM-ga
Tellimisel