Main
product range
Harmony Time Delay Relay
name of the device
RE22
type of product or equipment
Dual function relay
rated output current
8 A
timer type
Switching power
Complementary
[un] rated nominal voltage
24…240 V CA
24 V CC
[ics] rated service breaking capacity
2000 VA
maximum switching current
8 mA
tightening torque
0.6...1 Nm conforming to IEC 60947-1
case material
Auto-extinguible
minimum switching current
10mA at 5V
product weight
0,09 kg
power consumed in va
50 VA at 240 V AC
electrical life
100000 cycles for resistive load, 8 A at 250 V, AC
led status
Green LED (flash) for timing in progress
Green LED (fixed) for power ON
Yellow LED for relay powered
connection mode
Screw terminals, 2 x 1.5 mm² with cable end
Screw terminals, 2 x 2.5 mm² without cable end
safety reliability data
MTTFd = 182.6 years
B10d = 170000
mechanical endurance
10000000 cycle
width (w)
22,5 mm
power frequency
50...60 Hz +/- 5 %
power-on delay
100 ms
temperature drift
+/- 0,05 %/°C
voltage drift
+/- 0.2%/V
timing range
1…10 min
10…100 H
1…10 s
0,1…1 s
6…60 s
6…60 min
1…10 H
power consumed in w
0,7 W à 24 V CC
mounting bracket
35 mm DIN rail conforming to EN/IEC 60715
repeat accuracy
+/- 0.5% conforming to IEC 61812-1
control signal pulse width
30 ms
100 ms sous-charge
mounting position
Any position relative to the normal vertical mounting plane
order type
Front rotary knob
type and composition of contacts
2 C/O timed contact
voltage range of use
0.85 to 1.1 Us
dielectric strength
2.5 kV for 1 mA/1 minute at 50 Hz conforming to IEC 61812-1
recovery time
120 ms on de-energization
rated impulse withstand voltage
5 kV for 1.2...50 µs conforming to IEC 60664-1
5 kV conforming to IEC 61812-1
exact adjustment of the delay time
+/- 10 % full scale at 25 °C conforming to IEC 61812-1
maximum cut-off voltage
250V
logic output type
Relay
Environment
ip degree of protection
IP40 enclosure: conforming to IEC 60529
IP20 terminal block: conforming to IEC 60529
IP40 front panel: conforming to IEC 60529
product certificates
cULus
CE
EAC
CSA
RCM
CCC
GL
electromagnetic compatibility
Electrostatic discharge immunity test - test level: 6 kV (contact discharge) level 3 conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test - test level: 8 kV (contact discharge) air)level 3 conforming to EN/IEC 61000-4-2
Fast transient immunity test - test level: 1 kV (capacitive connection clip)level 3 conforming to IEC
61000-4-4 fast transient immunity - test level: 2 kV (direct contact) level 3 conforming to IEC 61000-4-4
Surge immunity test - test level: 1 kV (differential mode) level 3 conforming to IEC 61000 -4-5
Surge immunity test - test level: 2 kV (common mode) level 3 conforming to IEC 61000-4-5
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V (0.15...80 MHz) level 3 conforming to IEC 61000-4-6
Electromagnetic field immunity test - test level: 10 V/m (80 MHz...1 GHz) level 3 conforming to IEC 61000-4-3
Immunity to micro-breaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to micro-breaks and voltage sags - test level: 100 % (20 ms) conforming to IEC 61000-4-11
Conducted and radiated emissions class B conforming to EN 55022
immunity to micro-breaks
10 ms
standards
EN 61000-6-3
EN 61000-6-4
EN 61000-6-2
IEC 61812-1
EN 61000-6-1
relative humidity
93 %, without condensation conforming to IEC 60068-2-30
operating ambient air temperature
-20…60 °C
storage room temperature
-30…60 °C
mechanical shock resistance
15 gn for 11 ms conforming to IEC 60068-2-27
European regulation
2004/108/CE - electromagnetic compatibility
2006/95/CE - low voltage directive
vibration resistance
20 m/s² (f= 10...150 Hz) conforming to IEC 60068-2-6
insulation resistance
100 MΩ at 500 V DC conforming to IEC 60664-1