Default
Seeria
Compact INS/INV
Main
Range
ComPacT
sectioning ability
Yes
type of product or equipment
Isolator switch
Product Name
ComPacT INS
[ui] rated insulation voltage
1000 V AC 50/60 Hz
visible cut
Non
Complementary
"no" connection
70 mm
[icm] rated short circuit making capacity
105 kA disconnector only 690 V AC at 50/60 Hz
105 kA with upstream protection circuit breaker 690 V AC at 50/60 Hz
[ie] rated operational current
AC-21B: 2500 ACA 50/60 Hz 220/240 V
AC-21B: 2500 ACA 50/60 Hz 380/415 V
AC-21B: 2500 ACA 50/60 Hz 440/480 V
AC-21B: 2500 A CA 50/60 Hz 480 V NEMA
AC-21B: 2500 A CA 50/60 Hz 500/525 V
AC-21B: 2500 A CA 50/60 Hz 660/690 V
AC-22B: 2500 A CA 50/60 Hz 220/240 V
AC-22B: 2500 A CA 50/60 Hz 380/415 V
AC-22B: 2500 A CA 50/60 Hz 440/480 V
AC-22B: 2500 A CA 50/60 Hz 480 V NEMA
AC- . 22B: 2500 A AC 50/60 Hz 500/525 V
AC-22B: 2500 A AC 50/60 Hz 660/690 V
DC-21B: 2500 A DC 125 V 2 Series Poles
DC-22B: 2500 A DC 125 V 2 poles in series
[ue] rated operational voltage
125 V CC
690 V CA 50/60 Hz
[icw] rated short-time withstand current
50 kA for 0.5 s conforming to IEC 60947-3
11 kA for 30 s conforming to IEC 60947-3
13 kA for 20 s conforming to IEC 60947-3
30 kA for 3 s conforming to IEC 60947-3
50 kA for 0.8 s conforming to IEC 60947-3
50 kA for 1s conforming to IEC 60947-3
[ith] conventional thermal current
2500 A at 60 °C
Handle colour
Black
intermittent duty class
Class 120 - 60 %
Handle front plate colour
440 mm
[uimp] rated impulse withstand voltage
12 kV
mechanical life
3000 cycle
product weight
35 kg
fully apparent cut
Yes
mode d'installation
Fixed
electrical life
AC-21B: 100 cycles 220/240 V AC 50/60 Hz
AC-21B: 100 cycles 380/415 V AC 50/60 Hz
AC-21B: 100 cycles 440/480 V AC 50/60 Hz
AC-21B: 100 cycle 480 V AC 50/60 Hz conforming to NEMA
AC-21B: 100 cycle 500/525 V AC 50/60 Hz
AC-21B: 100 cycle 660/690 V AC 50/60 Hz
AC-22B: 100 cycle 220/ 240 V AC 50/60 Hz
AC-22B: 100 cycle 380/415 V AC 50/60 Hz
AC-22B: 100 cycle 440/480 V AC 50/60 Hz
AC-22B: 100 cycle 480 V AC 50/60 Hz conforming to NEMA
AC-22B: 100 cycles 500/525 V AC 50/60 Hz
AC-22B: 100 cycles 660/690 V AC 50/60 Hz
DC-21B: 100 cycles 125 V DC 2 poles in series
DC-22B : 100 cycles 125 V DC 2 poles in series
width (w)
347,5 mm
network frequency
50/60 Hz
upstream connection
Façade
downstream connection
Façade
assigned department
Uninterrupted
depth
227,5 mm
mounting bracket
Platine
Rail
Network type
CA
CC
order type
Direct front rotary handle
Poles description
3P
Environment
degree of pollution
3
ip degree of protection
IP40 conforming to CEI 60529
product certificates
KEMA-KEUR
operating ambient temperature
-25…70 °C
standards
CEI 60947-1
CEI 60947-3
shock resistance ik
IK07 conforming to EN 50102
storage room temperature
-50…85 °C