LV848498 – Schneider Electric

EAN: 3606480811319
810,21 € KM-ta
1 004,66 € KM-ga
MicroLogic 2.0X juhtseade, MasterPact MTZ2/MTZ3, tõmbevoolukaitsmed, LI kaitsmed - Schneider Electric
1 004,66 €
SPETSIFIKATSIOONID
Default
Seeria Masterpact MTZ
Main
Range Masterpact
circuit breaker application CEI distribution rules
name of the device Micrologic 2.0 X
type of product or equipment Control unit
trigger protection functions THAT
poles 3P
4P
type of trigger Electronic
protected poles 4P 3d
4P 3d + N/2
4P 4d
3P 3d
4P 3d + OSN
Complementary
[ii] instantaneous pick-up adjustment range 1.5…10 x Ir adjustable in steps of 0.5 x Ir with embedded HMI
1.5…10 x Ir adjustable in steps of 0.1 x Ir with Ecoreach software or Masterpact MTZ mobile application
[ue] rated operational voltage 690 V CA, +/- 10 %
application Protection, monitoring and control of equipment
range compatibility Masterpact (Masterpact MTZ2 H2 corrosion protection) circuit breaker
Masterpact (Masterpact MTZ2 H10) circuit breaker
Masterpact (MasterPacT MTZ2) circuit breaker
Masterpact (MasterPacT MTZ3) circuit breaker
[ir] long time pick-up adjustment range 0.4…1 x In adjustable in steps of 1 A
trigger caliber 400 A
4000 A
3200 A
630 A
800 A
1250 A
1000 A
5000 A
1600 A
2000 A
2500 A
6300 A
[li mode] instantaneous delay adjustment range 20 ms in standard
accuracy class Class 5: current total harmonic distortion rate THD (I)
Class 0.5: unbalance voltage
Class 1: active and reactive energy by pulse counting (+/- Wh, +/- VAR.h)
Class 2 : total harmonic distortion rate in voltage THD (V)
data logging Min/max number of instantaneous values
​​Alarm
logs Maintenance
logs Event reports
Timestamps
Data reports
mounting location Indoor use only
[tr] long-time delay adjustment range 12.5…600 s at 1.5 x Jump
0.5…24 s at 6 x Jump
0.7…16.6 s at 7.2 x Jump
mode d'installation Extract
type of measurement power meter
energy management Active, reactive and apparent energy measurement (standard)
Electrical network measurement (standard)
Energy measurement (standard)
network frequency 50/60 Hz
thermal memory Yes
frequency measurement range 40…70 Hz
measurement accuracy Power factor: +/- 1 %
Active energy Ep INPUT/OUTPUT/tot: +/- 1 % - 10...10 GWh
Reactive energy Ep INPUT/OUTPUT/tot: +/- 2 % - 10...10 GVARh
Apparent energy Es INPUT/OUTPUT/tot: +/- 1 % - 10...10 GVAh
Unbalance current: +/- 0.5 %
Frequency: +/- 0.005 Hz
Voltage V21, V32, V13, VLLavg: + /- 0.5% 208...690 x 1.2 V
Voltage V21, V32, V13, VLNavg: +/- 0.5% 120...400 x 1.2 V
Apparent power S, S1, S2, S3, Sdemanded: +/- 1 %
Active power P, P1, P2, P3, P demanded: +/- 1 %
Reactive power Q, Q1, Q2, Q3, Q demanded: +/- 2 %
Current I1, I2, I3 , Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A
Courant I1, I2, I3, Imoy, Idemande pour MTZ2: +/- 0,5 % 40...4000 x 1,2 A
Courant I1, I2, I3, Imoy, Idemande pour MTZ3: +/- 0,5 % 80...6300 x 1,2 A
communication port protocol Bluetooth 4.0 LE peer-to-peer 30 kbit/s
NFC peer-to-peer 28800 baud conforming to ISO 15963
USB peer-to-peer 115 kbaud
Network type THAT
type of network and machine diagnostics System Health (HMI) Overview: Circuit Breaker Health (as standard)
Contacts State: Circuit Breaker Health (as standard)
Micrologic Lifetime: Circuit Breaker Health (as standard) as standard)
Trip cause indication: circuit breaker trip cause (as standard)
Identification card: diagnostic data (as standard)
Configured alarm summary: diagnostic data (as standard)
Monitored function: diagnostic data (as standard)
Operation: diagnostic data (as standard)
Micrologic test: test (as standard)
Protection test: test (as standard)
Selectivity test: test (as standard)
Trip context information: Management of a trip event (as standard)
Operation: advanced diagnostics (as standard)
Circuit breaker life: circuit breaker health status (as standard)
timer setting type Adjustable in steps of 0.5 s
type of instantaneous threshold adjustment (ii) Adjustable
measuring voltage 145,6 V CA 50/60 Hz per phase
828 V CA 50/60 Hz per phase
type of display LCD display - 128 x 96 pixels
kind of protection Instantaneous short-circuit protection conforming to ANSI 50
Overload (long) conforming to ANSI 49
zsi logic selective latch area Without
type of count Current I1, I2, I3, In, Ig: maximum (as standard)
Average voltage Vavg (as standard)
Active power P, P1, P2, P3 (as standard)
Reactive power Q, Q1, Q2, Q3 (as standard)
Power apparent current S, S1, S2, S3 (as standard)
Power factor (as standard)
Frequency (as standard)
Current total harmonic distortion rate THD (I): inst, avg, min avg, max avg fundamental voltage (as standard )
Current total harmonic distortion rate THD (I): inst, avg, min avg, max ag voltage RMS (as standard)
Voltage V21, V32, V13, V1, V2, V3: instantaneous (as standard)
Voltage V21, V32 , V13, V1, V2, V3: minimum (as standard)
Voltage V21, V32, V13, V1, V2, V3: maximum (as standard)
Total harmonic distortion in voltage THD (V): inst, avg, min avg, max avg fundamental voltage (as standard)
Total harmonic distortion rate in voltage THD (V): inst, avg, min avg, max avg RMS voltage (as standard)
Current demand I1, I2, I3, In, Iavg (as standard)
Active (P), reactive (Q) and apparent power (S) requested (as standard)
Environment
degree of pollution 3 conforming to IEC 60947-1
environment characteristic Wet location not approved for use conforming to IEC 61010-1
operating altitude <= 2000 m sans déclassement
<= 4000 m with operational voltage derating 600 V AC
<= 5000 m with operational voltage derating 560 V AC
electromagnetic compatibility Electrostatic discharge immunity test conforming to IEC 6100-4-11
Electromagnetic field disturbance conforming to IEC 61000-4-3
Electrical fast transient immunity test conforming to IEC
61000-4-4 immunity to shock waves 1.2/50 µs conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Conducted and radiated emissionsA conforming to CISPR22
overvoltage category IV conforming to IEC 61010-1
standards EN/CEI 60947-1
EN/IEC 60092-202
EN/CEI 60255-1
EN/CEI 60947-2
EN/CEI 61010-1
measurement category Category IV conforming to IEC 61010-2-30
relative humidity 95 % at 55 °C conforming to IEC 60068-2-30
operating temperature -25…70 °C (fonctionnement)
-35 °C (for start-up of product)
KKK ja hinna lisateave

Võta meiega ühendust

Professionaalne elektriseadmete müük Eestis, Lätis, Leedus ja Soomes. Sertifitseeritud madalpinge komponendid, kaitselülitid, kontaktorid ja tööstusautomaatika lahendused. Sama päeva hinnapakkumised ja kiire tarne Baltikumis ja Soomes

Baltelec
+372 5326 4976

E–R 9:00–17:00

info@baltelec.ee

Vastame 2 tunni jooksul

Schneider Electric LV848498 on lahendus kategooriast Masterpact MTZ, mis on mõeldud ettevõtetele. BaltElec tegeleb hulgimüügi ja distributsiooniga Eestis, Lätis, Leedus ja Soomes.

  • Autentne Schneider Electric toode, vastavusdokumendid päringu alusel.
  • Mahupõhine hinnastus – küsi pakkumist suuremate koguste jaoks (võimalik, et sätestame MOQ).
  • Kiire tarne Baltikumis ning Soomes; koostöö tunnustatud kulleritega.
  • Tehniline tugi ja nõustamine valikul vastavalt Sinu rakendusele.

Hind: Küsi eripakkumist. Hind sõltub kogusest, tarne- ja maksetingimustest.