LC3K09P7 - TeSys K tähtedelta starter 3 x 3P (3 NO) 9 A 230 V vahelduvvoolu mähis - Schneider Electric - TeSys K tähtedelta starter 3 x 3P (3 NO) 9 A 230 V vahelduvvoolu mähis - Schneider Electric - 0
LC3K09P7 - TeSys K tähtedelta starter 3 x 3P (3 NO) 9 A 230 V vahelduvvoolu mähis - Schneider Electric - TeSys K tähtedelta starter 3 x 3P (3 NO) 9 A 230 V vahelduvvoolu mähis - Schneider Electric - 0
Tellimisel

LC3K09P7 – Schneider Electric

145,35 € KM-ta
180,23 € KM-ga
TeSys K tähtedelta starter 3 x 3P (3 NO) 9 A 230 V vahelduvvoolu mähis - Schneider Electric
180,23 €
SPETSIFIKATSIOONID
Default
Seeria TeSyS K
Main
Contactor application Motor control
Device short name LC3K
Interlocking type Mechanical
Range TeSys
[uc] control circuit voltage 230 V AC 50/60 Hz
Product Name TeSys K
[ui] rated insulation voltage Power circuit: 750 V conforming to VDE 0110 group C
Power circuit: 690 V conforming to IEC 60947
Power circuit: 690 V conforming to BS 5424
Power circuit: 690 V conforming to NF C 20-040
Power circuit: 600 V CSA 22-2 certified
Power circuit: 600 V UL 508 certified
Signalling circuit: 750 V conforming to VDE 0110 group C
Signalling circuit: 690 V conforming to IEC 60947
Signalling circuit: 690 V conforming to BS 5424
Signalling circuit: 690 V conforming to NF C 20-040
Signalling circuit: 600 V CSA 22-2 certified
Signalling circuit: 600 V UL 508 certified
control circuit type AC at 50/60 Hz
motor power kW 4 kW at 220/230 V AC 50/60 Hz
7.5 kW at 380/400 V AC 50/60 Hz
7.5 kW at 415 V AC 50/60 Hz
7.5 kW at 440 V AC 50/60 Hz
Complementary
[ie] rated operational current 9 A (at <50 °C) at <= 440 V AC AC-3 for power circuit
[ue] rated operational voltage Power circuit: <= 690 V AC 25...400 Hz
Handle front plate colour 110 mm
Product or component type Star delta starter
tightening torque 0.8…1.3 N.m - on screw clamp terminals Philips No 2
0.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm
0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
[uimp] rated impulse withstand voltage 8 kV
Auxiliary contact composition 1 NC for KM1 star contactor
Connections - terminals Screw clamp terminals 1 1.5…4 mm² - cable stiffness: solid
Screw clamp terminals 1 0.75…4 mm² - cable stiffness: flexible without cable end
Screw clamp terminals 1 0.34…2.5 mm² - cable stiffness: flexible with cable end
Screw clamp terminals 2 1.5…4 mm² - cable stiffness: solid
Screw clamp terminals 2 0.75…4 mm² - cable stiffness: flexible without cable end
Screw clamp terminals 2 0.34…1.5 mm² - cable stiffness: flexible with cable end
minimum switching current 5 mA for signalling circuit
Auxiliary contacts type Mechanically linked conforming to IEC 60947-5-1 3 x 1 NO + 1 NC
Mirror contact conforming to IEC 60947-4-1 3 x 1 NC
Control circuit voltage limits Operational: 0.8...1.15 Uc (at <50 °C)
Drop-out: 0.2...0.75 Uc (at <50 °C)
width (w) 150 mm
mechanical robustness Vibrations contactor open: 2 Gn, 5...300 Hz
Vibrations contactor closed: 4 Gn, 5...300 Hz
Shocks contactor closed, on X axis: 10 Gn for 11 ms
Shocks contactor opened, on X axis: 6 Gn for 11 ms
Shocks contactor closed, on Y axis: 15 Gn for 11 ms
Shocks contactor opened, on Y axis: 10 Gn for 11 ms
Shocks contactor closed, on Z axis: 15 Gn for 11 ms
Shocks contactor opened, on Z axis: 10 Gn for 11 ms
Flame retardance V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
Heat dissipation 1.3 W
Net weight 0.74 kg
Hold-in power consumption in va 4.5 VA (at 20 °C)
Mounting support Rail
depth 94 mm
Inrush power in va 30 VA (at 20 °C)
mechanical durability 10 Mcycles
electrical durability 1.3 Mcycles 9 A AC-3 at Ue <= 440 V
Device presentation Pre-wired
Maximum operating rate 12 cyc/h 60 °C
minimum switching voltage 17 V for signalling circuit
Power pole contact composition 3 x 3 NO
coil technology Without built-in suppressor module
Starting time 30 s
Poles description 3 x 3P
Utilisation category AC-3
Environment
Ambient air temp for storage/transportation -50…80 °C
ip degree of protection IP20 conforming to VDE 0106
operating altitude 2000 m without derating
overvoltage category III
standards IEC 60947
NF C 63-110
VDE 0660
protective treatment TC conforming to IEC 60068
TC conforming to DIN 50016
insulation resistance > 10 MOhm for signalling circuit
KKK ja hinna lisateave

Võta meiega ühendust

Professionaalne elektriseadmete müük Eestis, Lätis, Leedus ja Soomes. Sertifitseeritud madalpinge komponendid, kaitselülitid, kontaktorid ja tööstusautomaatika lahendused. Sama päeva hinnapakkumised ja kiire tarne Baltikumis ja Soomes

Baltelec
+372 5326 4976

E–R 9:00–17:00

info@baltelec.ee

Vastame 2 tunni jooksul

LC3K09P7 on lahendus kategooriast Tööstuslikud kontaktorid, mis on mõeldud professionaalidele. BaltElec tegeleb mahupõhise müügi ja distributsiooniga Eestis, Lätis, Leedus ja Soomes.

  • Originaal Schneider Electric toode, vastavusdokumendid päringu alusel.
  • Projektihind – küsi pakkumist suuremate koguste jaoks (võimalik, et sätestame MOQ).
  • Kiire tarne Baltikumis ning Soomes; koostöö tunnustatud kulleritega.
  • Tehniline tugi ja ettepanekud sobivuse kohta vastavalt Sinu rakendusele.

Hind: Küsi eripakkumist. Hind sõltub kogusest, tarne- ja maksetingimustest.

KKK tootele LC3K09P7 - Schneider Electric

Hiljuti vaadatud
LC3K09P7 - Schneider Electric
TeSys K tähtedelta starter 3 x 3P (3 NO) 9 A 230 V vahelduvvoolu mähis
145,35 € KM-ta
180,23 € KM-ga
Tellimisel