Kõik kategooriad
Võrdle Ostukorv
LC2D150P7 - TeSys LC2D - pöördkontaktor - 3P - AC-3 440V - 150A - 230Vac mähis. - Schneider Electric - TeSys LC2D - pöördkontaktor - 3P - AC-3 440V - 150A - 230Vac mähis. - Schneider Electric - 0
LC2D150P7 - TeSys LC2D - pöördkontaktor - 3P - AC-3 440V - 150A - 230Vac mähis. - Schneider Electric - TeSys LC2D - pöördkontaktor - 3P - AC-3 440V - 150A - 230Vac mähis. - Schneider Electric - 0
Tellimisel

LC2D150P7 – Schneider Electric

EAN: 3389110509656
752,97 € KM-ta
933,69 € KM-ga
TeSys LC2D - pöördkontaktor - 3P - AC-3 440V - 150A - 230Vac mähis. - Schneider Electric
933,69 €
SPETSIFIKATSIOONID
Default
Seeria TeSyS Deca kontaktorid
Main
Range TeSys
[uc] control circuit voltage 230 V AC 50/60Hz
job category AC-1
AND-3
name of the device LC2D
switch application Motor control (AC-3)
Resistive load (AC-1)
type of product or equipment Reversing contactor
Product Name TeSys D
TeSys Deca
[ui] rated insulation voltage Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signaling circuit: 690 V conforming to IEC 60947-1
Signaling circuit: 600 V CSA certified
Signaling circuit: 600 V UL certified
Power circuit: 1000 V conforming to IEC 60947-4-1
control circuit type AC at 50/60 Hz
engine power hp 40 hp at 200/208 V AC 60 Hz for 3 motor phases
50 hp at 230/240 V AC 60 Hz for 3 motor phases
100 hp at 460/480 V AC 60 Hz for 3 motor phases
125 hp at 575/600 V AC 60 Hz for 3 motor phases
composition of the power pole contacts 3F
motor power kW 40 kW at 220...230 V AC 50 Hz
75 kW at 380...400 V AC 50 Hz
80 kW at 415...440 V AC 50 Hz
90 kW at 500 V CA 50 Hz
100 kW at 660.. .690 V AC 50 Hz
75 kW at 1000 V AC 50 Hz
average impedance 0.6 mOhm - Ith 200 A 50 Hz for power circuit
Complementary
[ie] rated operational current 200 A (at <60°C) at <= 440 V AC AC-1 for power circuit
150 A (at <60°C) at <= 440 V AC AC-3 for power circuit
[ue] rated operational voltage Power circuit: <= 1000 V AC 25...400 Hz
Power circuit: <= 300 V DC
[ics] rated service breaking capacity 1400 A at 440 V for power circuit conforming to IEC 60947
[icw] rated short-time withstand current 250 A at <40°C - 10 min for
580 A power circuit at <40°C - 1 min for
1200 A power circuit at <40°C - 10 s for
1400 A power circuit at <40°C - 1s for
100 A power circuit - 1s for
120 A signaling circuit - 500 ms for
140 A signaling circuit - 100 ms for signaling circuit
[ith] conventional thermal current 200 A at <60 °C) for power circuit
caliber of the fuse to be associated 10 A gG for signaling circuit conforming to IEC 60947-5-1
315 A gG at <= 690 V type 1 coordination for power circuit
250 A gG at <= 690 V type 2 coordination for power circuit
Handle front plate colour 158 mm
tightening torque Remote control: 1.2 Nm - on screw-clamp terminals - with flat screwdriver Ø 6 mm
Remote control: 1.2 Nm - on screw-clamp terminals - with Phillips No. 2 screwdriver
Power circuit: 12 Nm - on connector hexagonal screw head 4 mm
Remote control: 1.2 Nm - on screw clamp terminals - with pozidriv n°2 screwdriver
[uimp] rated impulse withstand voltage 8 kV conforming to IEC 60947
auxiliary contacts 1 "O" + 1 "F"
average fuel consumption when going 2…18 VA (at 20°C) cos phi 0.9 60 Hz
2…18 VA (at 20°C) cos phi 0.9 50 Hz
mechanical life 8000000 cycle
minimum switching current 5 mA for signaling circuit
product weight 6,4 kg
type of auxiliary contacts mechanically linked type 1 NC + 1 NO conforming to IEC 60947-5-1
1 NC mirror contact type conforming to IEC 60947-4-1
electrical life 0.85 Mcycles 150 A AC-3 at Ue <= 440 V
1 Mcycles 200 A AC-1 at Ue <= 440 V
connection mode Remote control: screw clamp terminals 2 cable(s) 1...2.5 mm²flexible with cable end
Remote control: screw clamp terminals 1 cable(s) 1...2.5 mm²flexible without cable end
Remote control: screw terminals- clamp 2 cable(s) 1...2.5 mm²flexible without cable end
Remote control: screw clamp terminals 1 cable(s) 1...2.5 mm²flexible with cable end
Remote control: screw clamp terminals 1 cable(s) 1...2.5 mm²rigid without cable end
Remote control: screw clamp terminals 2 cable(s) 1...2.5 mm²rigid without cable end
Power circuit: connector 1 cable(s) 10...120 mm²flexible without cable end
Power circuit : connector 2 flexible 10...50 mm² cable(s) without cable end
Power circuit: connector 1 cable(s) 10...120 mm²flexible with cable end
Power circuit: connector 2 cable(s) 10...50 mm²flexible with cable end
Power circuit: connector 1 cable(s) 10...120 mm²rigid without cable end
Power circuit : connector 2 cable(s) 10...50 mm² rigid without cable end
type of lock Electrical
Mechanical
control circuit voltage range 0.3...0.5 Uc -40...70 °C dropout AC 50/60 Hz
0.8...1.15 Uc -40...55 °C operational AC 50/60 Hz
1...1.15 Uc 55…70 °C operational AC 50/60 Hz
width (w) 266 mm
mechanical robustness Contactor open vibrations: 2 Gn, 5 to 300 Hz
Contactor closed vibrations: 4 Gn, 5 to 300 Hz
Contactor closed shocks: 15 Gn for 11 ms
Contactor open shocks: 6 Gn for 11 ms
Flame retardance V1 conforming to UL 94
product presentation Pre-assembled with reversing busbars
rated rms inrush power 140 A AC for signaling circuit conforming to IEC 60947-5-1
250 A DC for signaling circuit conforming to IEC 60947-5-1
1660 A at 440 V for power circuit conforming to IEC 60947
depth 148 mm
mounting bracket Rail
Platine
frequency With
signaling circuit frequency 25 to 400 Hz
calling power goes 280…350 VA 60 Hz cos phi 0.9 (at 20 °C)
280…350 VA 50 Hz cos phi 0.9 (at 20 °C)
operating time 20…35 ms closing
40…75 ms opening
power loss per pole 24 W AC-1
13,5 W AC-3
security reliability level B10d = 1369863 contactor cycle with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 contactor cycle with mechanical load conforming to EN/ISO 13849-1
max command speed 1200 cycles/h at <60°C
minimum switching voltage 17 V for signaling circuit
non-overlap time 1.5 ms on de-
energization between NC and NO contact 1.5 ms on excitation between NC and NO contact
coil technology Built-in bi-directional peak limit diode suppressor
Poles description 3P
Environment
degree of pollution 3
ip degree of protection IP20 front face conforming to IEC 60529
operating altitude 0...3000 m
product certificates BV
CCC
CSA
DNV
GL
RINA
UL
EAC
UKCA
overvoltage category III
standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
CEI 60947-4-1
CEI 60947-5-1
UL 508
fire resistance 850 °C conforming to IEC 60695-2-1
thermal dissipation 3…4.5 W at 50/60 Hz
operating temperature -40…60 °C
60…70 °C with current reduction
storage room temperature -60…80 °C
climatic resistance conform to IACS E10
protective treatment TH conforming to IEC 60068-2-30
insulation resistance > 10 MΩ for signaling circuit
KKK ja hinna lisateave

Võta meiega ühendust

Professionaalne elektriseadmete müük Eestis, Lätis, Leedus ja Soomes. Sertifitseeritud madalpinge komponendid, kaitselülitid, kontaktorid ja tööstusautomaatika lahendused. Sama päeva hinnapakkumised ja kiire tarne Baltikumis ja Soomes

Baltelec
+372 5326 4976

E–R 9:00–17:00

info@baltelec.ee

Vastame 2 tunni jooksul

LC2D150P7 on lahendus kategooriast Tööstuslikud kontaktorid, mis on mõeldud suurettevõtetele. BaltElec tegeleb hulgimüügi ja toodete levitamisega Eestis, Lätis, Leedus ja Soomes.

  • Autentne Schneider Electric toode, vastavusdokumendid päringu alusel.
  • Projektihind – küsi pakkumist suuremate koguste jaoks (võimalik, et sätestame MOQ).
  • Kiire tarne Baltikumis ning Soomes; koostöö logistikapartneritega.
  • Tehniline tugi ja ettepanekud sobivuse kohta vastavalt Sinu rakendusele.

Hind: Küsi projektipakkumist. Hind sõltub kogusest, tarne- ja maksetingimustest.

KKK tootele LC2D150P7 - Schneider Electric

Hiljuti vaadatud
LC2D150P7 - Schneider Electric
TeSys LC2D - pöördkontaktor - 3P - AC-3 440V - 150A - 230Vac mähis.
752,97 € KM-ta
933,69 € KM-ga
Tellimisel