Main
product range
TeSys F
Range
TeSys
[uc] control circuit voltage
220...230 V CC
220...240 V CA 40...400 Hz
job category
AC-4
AC-1
AC-3
name of the device
LC1F
switch application
Motor control (AC-3)
Resistive load (AC-1)
type of product or equipment
contactor
[ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 gr C
control circuit type
Standard DC
AC at 40...400 Hz
composition of the power pole contacts
3F
motor power kW
450 kW at 1000 V AC 50/60 Hz (AC-3)
450 kW at 500 V AC 50/60 Hz (AC-3)
475 kW at 660...690 V AC 50/60 Hz (AC-3)
110 kW at 400 V AC 50/60 Hz (AC-4)
450 kW at 380...400 V AC 50/60 Hz (AC-3)
450 kW at 415 V AC 50/60 Hz (AC-3)
450 kW à 440 V AC 50/60 Hz (AC-3)
250 kW à 220...230 V AC 50/60 Hz (AC-3)
average impedance
0,12 mOhm - Ith 1000 A 50 Hz
Complementary
[ie] rated operational current
1000 A (at <40°C) at <= 440 V AC AC-1
800 A (at <55°C) at <= 440 V AC AC-3
[ue] rated operational voltage
<= 1000 V CA 50/60 Hz
<= 460 V CC
compatibility code
LC1F
[ics] rated service breaking capacity
6400 A conforming to IEC 60947-4-1
[icw] rated short-time withstand current
5500 A at <40°C - 10 s
4600 A at <40°C - 30 s
3600 A at <40°C - 1 min
2600 A at <40°C - 3 min
1700 A at <40°C - 10 min
[ith] conventional thermal current
1000A at <40°C)
caliber of the fuse to be associated
1000 A gG at <= 440 V
800 A aM at <= 440 V
average consumption on hold in w
12W at 20°C
Handle front plate colour
304 mm
tightening torque
Remote control: 1.2 Nm
Power circuit: 58 Nm
[uimp] rated impulse withstand voltage
8 kV
mechanical life
5 Mcycles
product weight
18,75 kg
connection mode
Remote control: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end
Remote control: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end
Remote control: screw clamp terminals 1 cable( s) 1…4 mm²flexible with cable end
Remote control: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Remote control: screw clamp terminals 1 cable(s) 1…4 mm²rigid without end cable
length Remote control: screw clamp terminals 2 cable(s) 1...4 mm² rigid without cable end
Power circuit: bar 2 cable(s) - busbar section: 60 x 5 mm
Power circuit: connection by bolting
control circuit voltage range
Operational: 0.85...1.1 Uc (at 55 °C)
Level loss: 0.3...0.5 Uc (at 55 °C)
width (w)
309 mm
depth
255 mm
engine power range
250…500 kW at 200…240 V 3 phases
250…500 kW at 380…440 V 3 phases
110…220 kW at 200…240 V 3 phases
250…500 kW at 480…500 V 3 phases
mounting bracket
Platinum
maximum inrush power in w
1900W (at 20°C)
operating time
40…50 ms opening
60…80 ms closing
power loss per pole
120 W AC-1
77 W AC-3
max command speed
600 cycles/h at <55°C
contactor coil voltage
220 V CC standard
230 V CC standard
220 V CA standard
230 V CA standard
240 V CA standard
motor starter type
Direct line contactor
Poles description
3P
Environment
ip degree of protection
IP20 front face with protectors conforming to IEC 60529
IP20 front face with protectors conforming to VDE 0106
operating altitude
3000 m without current reduction
product certificates
ABS
UL
CCC
CSA
RMRoS
CB
UKCA
ambient air temperature for operation
-5…55 °C
operating ambient temperature
-5…55 °C
overvoltage category
III
standards
CEI 60947-1
JIS C8201-4-1
EN 60947-4-1
EN 60947-1
CEI 60947-4-1
thermal dissipation
12W
storage room temperature
-60…80 °C
protective treatment
TH