Main
product range
TeSys F
Range
TeSys
[uc] control circuit voltage
400 V AC 40...400 Hz
job category
AC-4
AC-1
AC-3
name of the device
LC1F
switch application
Resistive load (AC-1)
Motor control (AC-3)
type of product or equipment
contactor
[ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 gr C
control circuit type
AC at 40...400 Hz
composition of the power pole contacts
3F
motor power kW
75 kW at 400 V AC 50/60 Hz (AC-4)
200 kW at 380...400 V AC 50/60 Hz (AC-3)
220 kW at 415 V CA 50/60 Hz (AC-3)
250 kW at 440 V AC 50/60 Hz (AC-3)
257 kW at 500 V AC 50/60 Hz (AC-3)
280 kW at 660...690 V AC 50/60 Hz (AC-3)
185 kW à 1000 V CA 50/60 Hz (AC-3)
110 kW à 220...230 V CA 50/60 Hz (AC-3)
average impedance
0,26 mOhm - Ith 500 A 50 Hz
Complementary
[ie] rated operational current
500 A (at <40°C) at <= 440 V AC AC-1
400 A (at <55°C) at <= 440 V AC AC-3
[ue] rated operational voltage
<= 1000 V CA 50/60 Hz
<= 460 V CC
compatibility code
LC1F
[ics] rated service breaking capacity
3200 A conforming to IEC 60947-4-1
[icw] rated short-time withstand current
3600 A at <40°C - 10 s
2400 A at <40°C - 30 s
1700 A at <40°C - 1 min
1200 A at <40°C - 3 min
1000 A at <40°C - 10 min
[ith] conventional thermal current
500A at <40°C)
caliber of the fuse to be associated
400 A aM at <= 440 V
500 A gG at <= 440 V
Handle front plate colour
206 mm
tightening torque
Remote control: 1.2 Nm
Power circuit: 35 Nm
[uimp] rated impulse withstand voltage
8 kV
average fuel consumption when going
15 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
mechanical life
10 Mcycles
product weight
9,1 kg
average consumption on call going
1075 VA, 40...400 Hz cos phi 0.9 (at 20°C)
connection mode
Remote control: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end
Remote control: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end
Remote control: screw clamp terminals 1 cable( s) 1…4 mm²flexible with cable end
Remote control: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Remote control: screw clamp terminals 1 cable(s) 1…4 mm²rigid without end cable
length Remote control: screw clamp terminals 2 cable(s) 1...4 mm² rigid without cable end
Power circuit: bar 2 cable(s) - busbar section: 30 x 5 mm
Power circuit: ring terminals 2 cable(s) 150 mm²
Power circuit: connection by bolting
control circuit voltage range
Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
Level drop: 0.3...0.5 Uc 40...400 Hz (at 55 °C)
width (w)
213 mm
depth
219 mm
engine power range
110…220 kW at 480…500 V 3 phases
110…220 kW at 380…440 V 3 phases
110…220 kW at 200…240 V 3 phases
250…500 kW at 480…500 V 3 phases
mounting bracket
Platinum
operating time
40…65 ms closing
100…170 ms opening
power loss per pole
65 W AC-1
42 W AC-3
max command speed
2400 cycles/h at <55°C
contactor coil voltage
400 V CA standard
motor starter type
Direct line contactor
Poles description
3P
Environment
ip degree of protection
IP20 front face with protectors conforming to IEC 60529
IP20 front face with protectors conforming to VDE 0106
operating altitude
3000 m without current reduction
product certificates
RMRoS
ABS
UL
CB
RINA
LROS (Lloyds register of shipping)
DNV
BV
CSA
UKCA
ambient air temperature for operation
-40…70 °C
operating ambient temperature
-5…55 °C
overvoltage category
III
standards
JIS C8201-4-1
CEI 60947-4-1
EN 60947-4-1
CEI 60947-1
EN 60947-1
thermal dissipation
14W
storage room temperature
-60…80 °C
protective treatment
TH