Main
product range
TeSys F
Range
TeSys
[uc] control circuit voltage
400 V AC 40...400 Hz
job category
AC-4
AC-1
AC-3
name of the device
LC1F
switch application
Motor control (AC-3)
Resistive load (AC-1)
type of product or equipment
contactor
[ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 gr C
control circuit type
AC at 40...400 Hz
composition of the power pole contacts
3F
motor power kW
160 kW at 380...400 V AC 50/60 Hz (AC-3)
180 kW at 415 V AC 50/60 Hz (AC-3)
200 kW at 440 V AC 50/60 Hz (AC-3)
200 kW at 500 V AC 50/60 Hz (AC-3)
220 kW at 660...690 V AC 50/60 Hz (AC-3)
160 kW at 1000 V CA 50/60 Hz (AC-3)
100 kW à 220...230 V AC 50/60 Hz (AC-3)
59 kW à 400 V AC 50/60 Hz (AC-4)
average impedance
0,28 mOhm - Ith 400 A 50 Hz
Complementary
[ie] rated operational current
400 A (at <40°C) at <= 440 V AC AC-1
330 A (at <55°C) at <= 440 V AC AC-3
[ue] rated operational voltage
<= 1000 V CA 50/60 Hz
<= 460 V CC
compatibility code
LC1F
[ics] rated service breaking capacity
2640 A conforming to IEC 60947-4-1
[icw] rated short-time withstand current
2650 A at <40°C - 10 s
1800 A at <40°C - 30 s
1300 A at <40°C - 1 min
900 A at <40°C - 3 min
750 A at <40°C - 10 min
[ith] conventional thermal current
400A at <40°C)
caliber of the fuse to be associated
400 A aM at <= 440 V
500 A gG at <= 440 V
Handle front plate colour
206 mm
tightening torque
Remote control: 1.2 Nm
Power circuit: 35 Nm
[uimp] rated impulse withstand voltage
8 kV
average fuel consumption when going
10 VA, 40...400 Hz cos phi 0.9 (at 20 °C)
mechanical life
10 Mcycles
product weight
8,6 kg
average consumption on call going
650 VA, 40...400 Hz cos phi 0.9 (at 20°C)
connection mode
Remote control: screw clamp terminals 1 cable(s) 1...4 mm²flexible without cable end
Remote control: screw clamp terminals 2 cable(s) 1...4 mm²flexible without cable end
Remote control: screw clamp terminals 1 cable( s) 1…4 mm²flexible with cable end
Remote control: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Remote control: screw clamp terminals 1 cable(s) 1…4 mm²rigid without end cable cross-section
Remote control: screw clamp terminals 2 cable(s) 1...4 mm² rigid without cable end
Power circuit: ring terminals 1 cable(s) 240 mm²
Power circuit: busbar 2 cable(s) - section of set bar diameter: 30 x 5 mm
Power circuit: connection by bolting
control circuit voltage range
Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
Level drop: 0.35...0.55 Uc 40...400 Hz (at 55 °C)
width (w)
213 mm
depth
219 mm
engine power range
55…100 kW at 200…240 V 3 phases
110…220 kW at 480…500 V 3 phases
110…220 kW at 380…440 V 3 phases
mounting bracket
Platinum
operating time
40…65 ms closing
100…170 ms opening
power loss per pole
44 W AC-1
31 W AC-3
max command speed
2400 cycles/h at <55°C
contactor coil voltage
400 V CA standard
motor starter type
Direct line contactor
Poles description
3P
Environment
ip degree of protection
IP20 front face with protectors conforming to IEC 60529
IP20 front face with protectors conforming to VDE 0106
operating altitude
3000 m without current reduction
product certificates
UL
BV
ABS
CB
RMRoS
RINA
LROS (Lloyds register of shipping)
CSA
DNV
UKCA
ambient air temperature for operation
-40…70 °C
operating ambient temperature
-5…55 °C
overvoltage category
III
standards
CEI 60947-1
EN 60947-4-1
EN 60947-1
CEI 60947-4-1
JIS C8201-4-1
thermal dissipation
8W
storage room temperature
-60…80 °C
protective treatment
TH