Complementary
4 quadrant operation possible
TRUE
with safety function safe brake management (sbc/sbt)
Faux
[un] rated nominal voltage
380…500 V - 15...10%
with safe direction (sdi) safety function
Faux
maximum switching current
Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC
with safety function safe operating stop (sos)
Faux
Handle front plate colour
184,0 mm
with safe position (sp) safety function
Faux
with safety function safe programmable logic
Faux
minimum switching current
Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC
product weight
2,1 kg
with safe speed monitor (ssm) safety function
Faux
marking
CE
ATEX
UL
CSA
EAC
RCM
mode d'installation
Wall mounting
with safety function safe stop 1 (ss1)
TRUE
with safety function safe stop 2 (ss2)
Faux
with safe torque off (sto) safety function
TRUE
width (w)
140 mm
with safely limited position (slp) safety function
Faux
network frequency
50...60 Hz
switching frequency
2...16 kHz adjustable
4...16 kHz with reduction factor
with safety function safely limited speed (sls)
TRUE
motor slip compensation
Automatic whatever the load
Adjustable 0…300%
Not available in voltage/frequency ratio (2 or 5 points)
base load current at high overload
8,0 A
prospective line short-circuit current
5 kA
depth
158,0 mm
line current
8.7 A at 380 V (high overload)
6.6 A at 500 V (high overload)
power dissipation in w
Fan: 74.0 W at 380 V, switching frequency 4 kHz
current maximum input current per phase
8,7 A
logic input
Positive logic (source)
Negative logic (sink)
standstill braking
4 x 2,5 mm² + 2 x 1 mm² + 2 x 0,14 mm²
mounting position
Vertical +/- 10 degrees
nominal switching frequency
4 kHz
maximum output frequency
0,599 kHz
kind of protection
Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overheating protection: drive
Short-circuit between motor phases: drive
Thermal protection: drive
access method
Esclave CANopen
number of analog inputs
3
number of logic inputs
7
number of analog outputs
1
number of logic outputs
3
synchronous motor control profile
Sensorless vector control
control profile for asynchronous motor
Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio - Energy saving, quadratic U/f Flux
vector control without sensor - Energy
saving Voltage/frequency ratio, 2 points
apparent power
5.7 kVA à 500 V (surcharge importante)
acceleration and deceleration ramps
Linear
U
S
CUS
Ramp switching Acceleration/deceleration ramp
adaptation
Acceleration/deceleration automatic stop with DC injection
integrated braking resistor
TRUE
transient overtorque
170…200% of rated motor torque
max output voltage
500V
symmetric network relative frequency tolerance
five %
analog input type
AI1 voltage: 0...10 V DC, impedance: 30 kOhm, 10 bit resolution
AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, 10 bit resolution
AI3 current: 0…20 mA (or 4- 20 mA, x-20 mA, 20-x mA or other models per configuration), impedance: 250 Ohm, 10 bit resolution
logic input type
STO safe torque off, 24 V DC, impedance: 1.5 kOhm
DI1…DI6 digital inputs, 24 V DC (30 V)
DI5 programmable as pulse train input: 0…30 kHz, 24 V DC (30 V )
analog output type
Current configurable by software AQ1: 0...20 mA impedance 800 Ohm, resolution 10 bits
Voltage configurable by software AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits
logic output type
DQ+ open collector 0…1 kHz 30 V DC 100 mA
DQ- open collector 0…1 kHz 30 V DC 100 mA
relay output type
Configurable relay R1A 1 NO electrical durability 100000 cycles
Configurable relay R1B 1 NO electrical durability 100000 cycles Configurable relay
R1C Configurable
relay R2A 1 NO electrical durability 100000 cycles
Configurable relay R2A
Environment
Ambient air temp for storage/transportation
-25…70 °C
degree of pollution
2
ip degree of protection
IP20
maximum shock acceleration (in operation)
150 m/s² at 11 ms
product certificates
CE
ATEX
NOM
GOST
EAC
RCM
KC
electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 6100-4-11 Radiated
radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
maximum acceleration under vibration stress (in operation)
10 m/s² at 13...200 Hz
overvoltage category
III
standards
EN/CEI 61800-5-1
control loop
Adjustable PID controller
operating temperature
-10…50 °C without derating
50…60 °C with reduction factor
storage room temperature
-25…70 °C
environmental class (in operation)
Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
air flow
37,7 m3/h
maximum deflection under vibration load (in operation)
1.5 mm at 2...13 Hz
permissible relative humidity (during operation)
Class 3K5 according to EN 60721-3
speed accuracy
+/-10% of nominal slip 0.2 Tn to Tn