Default
Seeria
Harmony XAC
Main
drop box application
Single speed hoist motor control
product range
Harmony XAC
[ithe] thermal current under enclosure
10 A
extensibility type
Complete, ready to use
name of the device
XACA
type of product or equipment
Command post during
[ui] rated insulation voltage
600 V (pollution degree 3)
type of electrical circuit
Remote
Complementary
product compatibility
ZB2BE102 for emergency stop
ZB2BE102 + ZB2BE101 for all instructions
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
case material
Polypropylene
cable entry
Rubber sleeve with stepped entry 8…26 mm
product weight
0,6 kg
description of iso n°1 terminals
(11-12)NC
(13-14)NO
command station composition
2 push buttons + 1 emergency stop button
color control station
Yellow
connection mode
Screw clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end
Screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end
contact operation
Slow-action
mechanical endurance
1000000 cycle
rated operational power in w
40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
48 W DC-13 for 1000000 cycle, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
65 W DC-13 for 1000000 cycles, operating rate <60 cyc/min at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
actuation force
13 N push button
8 N emergency stop
description of iso n°2 terminals
(11-12)NC
contact code designation
A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A
A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947 -5-1 appendix A
identification connectors
(11-12)NC
(13-14)NO
mechanical lock
With mechanical interlock
control button type
Stop pushbutton Ø 30 mm 1 N/C Latching
First push-button 1 N/C + 1 N/C upper, slow
Second push-button 1 N/C + 1 N/C lower, slow
maximum resistance between terminals
25 MΩ
short circuit protection
10 A protection fuse by fuse cartridge type gG
type of control station
Double isolation
Environment
ip degree of protection
IP65 conforming to IEC 60529
product certificates
GOST
CCC
operating ambient temperature
-25…70 °C
overvoltage category
Class II conforming to IEC 61140
standards
EN/CEI 60947-5-1
CSA C22.2 No 14
UL 508
EN/CEI 60204-32
shock resistance ik
IK08 conforming to EN 50102
storage room temperature
-40…70 °C
mechanical shock resistance
100 gn conforming to IEC 60068-2-27
vibration resistance
15 gn (f= 10...500 Hz) conforming to IEC 60068-2-6
protective treatment
TH