Default
Seeria
Harmony RE/RM
Main
product range
Harmony Control Relay
product specific application
For three-phase supply
switching capacity in va
1250 VA
job category
AC-12 conforming to IEC 60947-5-1
AC-13 conforming to IEC 60947-5-1
AC-14 conforming to IEC 60947-5-1
AC-15 conforming to IEC 60947-5-1
DC- 12 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
type of product or equipment
3-phase control relay
rated output current
5 A
relay name
RM17TG
[ui] rated insulation voltage
400 V conforming to IEC 60664-1
parameters monitored by the relay
Phase sequence Phase
failure detection (loss of 2 or more phases)
measuring range
208...440V tension CA
voltage and type of control circuit
208...440V
type of relay
Control relay
Complementary
contact description
2 "O/F"
response time
<= 130 ms (in the event of a fault)
output contacts
2 "OF"
tightening torque
0.6...1 Nm conforming to IEC 60947-1
case material
Self-extinguishing plastic
minimum switching current
10 mA at 5 V DC
product weight
0,13 kg
marking
THIS
power consumed in va
0…22 VA at 400 V AC 50 Hz
connection mode
Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with mouthpiece
safety reliability data
B10d = 850000
MTTFd = 924.6 years
control circuit voltage range
- 12 % + 10 % And
mechanical endurance
30000000 cycle
width (w)
17,5 mm
control circuit frequency
50...60 Hz +/- 10 %
power frequency
50/60 Hz +/- 10 %
power-on delay
650 ms
supply voltage limits
183…484 V CA
delay
Without
Local signalling
for relay on LED (yellow)
measurement voltage limits
183…484 V CA
mounting bracket
35 mm symmetrical DIN rail conforming to EN/IEC 60715
electrical stamina
10000 cycle
mounting position
All positions without derating
voltage detection threshold
< 100 VCA
voltage range of use
183...484V
command speed
<= 360 operations/hour full load
maximum cut-off voltage
250 V CA
250 V CC
Environment
degree of pollution
3 conforming to IEC 60664-1
ip degree of protection
IP20 conforming to IEC 60529 (terminals)
IP30 conforming to IEC 60529 (sheath)
product certificates
GOST
C-Tick
UL
CSA
GL
electromagnetic compatibility
Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Emission standard for residential/commercial/light-industrial environments conforming to EN/IEC 61000-6-3
Immunity for industrial environments conforming to EN /IEC 61000-6-2
overvoltage category
III conforming to IEC 60664-1
standards
EN/CEI 60255-1
relative humidity
95 % at 55 °C conforming to IEC 60068-2-30
operating temperature
-20…50 °C
storage room temperature
-40…70 °C
mechanical shock resistance
15 gn for 11 ms conforming to IEC 60255-21-1
where of non-dissipative shock
4 kV
European regulation
73/23/CEE - low voltage directive
89/336/CEE - electromagnetic compatibility
vibration resistance
0.35 mm (f= 5...57.6 Hz) conforming to IEC 60068-2-6
1 gn (f= 57.6...150 Hz) conforming to IEC 60255-21-1
dielectric test voltage
2 kV AC 50 Hz, 1 min
insulation resistance
> 500 MΩ at 500 V DC conforming to IEC 60255-5
> 500 MΩ at 500 V DC conforming to IEC 60664-1