Default
Seeria
Harmony XPE
Main
product range
Harmony XPE
name of the device
XPEA
type of product or equipment
foot switch
[ui] rated insulation voltage
500 V (pollution degree 3) conforming to EN/IEC 60947-1
500 V (pollution degree 3) conforming to NF C 20-040 group C
500 V (pollution degree 3) conforming to VDE 0110 gr C
300 V conforming to UL 508
300 V conforming to CSA C22.2 No 14
trigger mechanism
Without trigger mechanism
foot switch type
Single foot switch
Complementary
[ie] rated operational current
3 A, 240 V, AC-15, A300
0.27 A, 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
contact description
1 "O" + 1 "F"
[uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-1
cable entry
1 single hole for M20 cable gland
1 single hole for M16 cable gland
matter
Plastic
product weight
0,275 kg
connection mode
Screw clamp terminals, <= 1 x 2.5 mm² with or without cable end
Screw clamp terminals, <= 2 x 1.5 mm² with or without cable end
contact operation
1 floor
mechanical endurance
2000000 cycle
rated operational power in w
10 W DC-13, operating rate <60 cyc/mn, 5000000 cycles, 24 V, load factor: 0.5 conforming to EN/IEC 60947-5-1 annex C
4 W DC-13, operating rate <60 cyc/mn, 5000000 cycles, 120 V, load factor: 0.5 conforming to EN/IEC 60947-5-1 annex C
7 W DC-13, operating rate <60 cyc/mn, 5000000 cycles, 48 V, load factor: 0.5 conforming to EN/IEC 60947-5-1 annex C
Colour
Noir
positive aperture
With conforming to EN/IEC 60947-5-1 annex K
maximum resistance between terminals
25 MΩ conforming to IEC 60255-7 category 3
25 MΩ conforming to NF C 93-050 method A
short circuit protection
10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
10 A cartridge fuse type gG conforming to VDE 0660-200
Environment
ip degree of protection
IP43 conforming to IEC 60529
operating ambient temperature
-25…55 °C
overvoltage category
Class II conforming to EN/IEC 61140
Class II conforming to NF C 20-030
standards
EN/CEI 60947-5-1
storage room temperature
-40…70 °C
mechanical shock resistance
25 gn conforming to IEC 60068-2-27
vibration resistance
5 gn (f= 10...500 Hz) conforming to IEC 60068-2-6
protective treatment
TH