Main
pressure actuator
Membrane
product range
OsiSense XM
product specific application
-
name of the device
XMLB
type of product or equipment
Electromechanical pressure sensor
maximum deviation achievable at the top of the range
1,75 bar
[ui] rated insulation voltage
300 V conforming to UL 508
500 V conforming to EN/IEC 60947-1
300 V conforming to CSA C22.2 No 14
controlled fluid
Air (0…160°C)
Soft water (0…160°C)
Hydraulic oil (0…160°C)
type of electrical circuit
Remote
operation of auxiliary contacts
Snap action
material in contact with the fluid
FPM, FKM
Steel
minimum possible differential at low setting
0.16 bar (- 0.03 bar, + 0.05 bar)
minimum differential possible at high settings
0.21 bar (- 0.03 bar, + 0.05 bar)
setting range of a lower parameter
0,14…2,29 bar
setting range of a higher parameter
0,3…2,5 bar
maximum allowable accidental pressure
9 bar
burst pressure
18 bar
pressure rating
2,5 bar
gap type
Adjustable differential
pressure sensor type
Electromechanical pressure sensor
type of operation of the pressure sensor
Regulation between 2 thresholds
type of hydraulic connection
G 1/4 (female) conforming to ISO 228
Complementary
[in] rated current
3 A, B300, AC-15 (Ue = 120 V) conforming to EN/IEC 60947-5-1
1.5 A, B300, AC-15 (Ue = 240 V) conforming to EN/IEC 60947-5 -1
0.1 A, R300, DC-13 (Ue = 250 V) conforming to EN/IEC 60947-5-1
local display
With
Handle front plate colour
113 mm
[uimp] rated impulse withstand voltage
6 kV conforming to EN/IEC 60947-1
awg gauge
AWG 20 to AWG 14
case material
zinc alloy
cable entry
Cable gland 9…13 mm
product weight
1,015 kg
contact material
silver contacts
mechanical endurance
8000000 cycle
width (w)
55 mm
setting
outer
allowable overpressure per cycle
5 bar
terminal block type
4 bornes
depth
75 mm
repeat accuracy
2,00%
electrical connection
Screw clamp terminals, 1 x 0.5...2 x 2.5 mm²
1 Pg 13 connector
mounting position
All positions
max command speed
120 cyc/mn
type and composition of contacts
1 F/O
maximum resistance between terminals
25 mOhm conforming to IEC 255-7 category 3
25 mOhm conforming to NF C 93-050 method A
short circuit protection
10 A cartouche fusible, type gG (gl)
Environment
ip degree of protection
IP66 conforming to EN/IEC 60529
product certificates
CCC
BV
CSA
EAC
LROS (Lloyds register of shipping)
UL
class of protection against electric shock
Class I conforming to IEC 1140
Class I conforming to IEC 536
Class I conforming to NF C 20-030
operating ambient temperature
-25…70 °C
standards
EN/CEI 60947-5-1
CSA C22.2 No 14
UL 508
CE
storage room temperature
-40…70 °C
mechanical shock resistance
50 gn conforming to IEC 60068-2-27
vibration resistance
4 gn (f = 30...500 Hz) conforming to IEC 60068-2-6
protective treatment
TC version standard