Main
product range
Preventa safety automation
reliability data
DC > 99 % conforming to EN/ISO 13849-1
MTTFd = 243 years conforming to EN/ISO 13849-1
PFHd = 4.62E-9 1/h conforming to EN/IEC 62061
[uc] control circuit voltage
24V
module function
Two-channel wiring, emergency stop monitoring or protection
monitoring Emergency stop monitoring 2-channel wiring
Monitoring of a mobile protection
type of product or equipment
Preventa safety module
[ui] rated insulation voltage
300 V (pollution degree 2) conforming to IEC 60947-5-1
300 V (pollution degree 2) conforming to DIN VDE 0110 part 1
security level
Up to PL e/category 4 conforming to EN/ISO 13849-1
Up to category 3 conforming to EN/IEC 62061
security module name
XPSAF
start type
Configurable
use of security module
Emergency stop and switch control
Complementary
[un] rated nominal voltage
24 V CA - 15...10 %
24 V CC - 15...10 %
power consumption
30 mA at 24 V AC at over voltage supply
[ics] rated service breaking capacity
1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
[ith] conventional thermal current
18 A
caliber of the fuse to be associated
4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
maximum power consumption in va
5 VA CA
[uimp] rated impulse withstand voltage
4 kV overvoltage category III conforming to IEC 60947-5-1
4 kV overvoltage category III conforming to DIN VDE 0110 part 1
product weight
0,25 kg
minimum output current
10 mA for relay output
output thermal current
6 A per relay for relay output
connection mode
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² rigid with cable end cable cross
-section, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 1 x 0.25...1 x 2 .5 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.14 to 2 x 0.75 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0 .14...2 x 0.75 mm² rigid with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel
Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel
power frequency
50/60 Hz
Local signalling
3 LEDs
maximum line resistance
90 Ohm
maximum response time on opening of inputs
40 ms
minimum output voltage
17 V for relay output
mounting bracket
35 mm symmetrical DIN rail
synchro time between inputs
Unlimited
type of output
Relay instantaneous opening, 3 NO circuit(s), volt free
input protection type
Internal, electronic
Environment
ip degree of protection
IP20 (terminals) conforming to EN/IEC 60529
IP40 (housing) conforming to EN/IEC 60529
product certificates
UL
TÜV
CSA
standards
EN/CEI 60947-5-1
EN/ISO 13850
EN 60204-1
EN 1088/ISO 14119
operating ambient air temperature
-25…60 °C
storage room temperature
-40…85 °C