Main
Series name
General purpose
sensor name
XXS
detection system
Diffuse
Complementary
Product certifications
E2RCMcULusEcolab
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Current consumption
30 mA
marking
CE
Discrete output function
1 NO or 1 NC programmable
Enclosure material
PBT
Material
Plastic
function available
Software configurablewith synchronisation mode
switching frequency
11 Hz
Discrete output type
PNP
Front material
Resinepoxyrubber
electrical connection
Male connector M12 5 pins
Minimum size of detected object
Cylinder diameter 1 mm at 600 mm
Sensor type
Ultrasonic sensor
Voltage drop
2 VOLT
Shock resistance
30 gn in all 3 axes for 11 ms conforming to IEC 60068-2-27
Setting-up
Configurator softwareteach mode
Sensor design
Cylindrical M30
Status led
Output state: 1 LED (yellow), echo state: 1 LED (green)
Wiring technique
5-wire
Type of output signal
Discrete
Environment
ip degree of protection
IP65 conforming to IEC 60529, IP67
Range of product
Telemecanique Ultrasonic sensors XX
standards
CSA C22.2 No 14UL 508IEC 60947-5-2
vibration resistance
+/-1 mm conforming to IEC 60068-2-6 (f = 10-55 Hz)