Main
Body type
Fixed
Series name
Application
sensor name
XS8
Complementary
Product certifications
INERIS 16ATEX0037XIEC-Ex INE 16.0047X
[us] rated supply voltage
12...48 V DC with reverse polarity protection
Current consumption
0...15 mA no-load
detection face
5 positions turret head
marking
II2 D-Ex tb IIIC T85°C Db IP67
Device application
ATEX dust
Discrete output function
1 NO + 1 NC
Enclosure material
PBT
Detector flush mounting acceptance
Flush mountable
safety reliability data
MTTFd = 1546 years, PFHd = 7.4E-8 1/h, SFF = 92 %, DC = 75 % with appropriate safety controller
Differential travel
3...15% of Sr
Material
Plastic
switching frequency
<= 300 Hz
Discrete output type
PNP
switching capacity in ma
<= 200 mA with overload and short-circuit protection
repeat accuracy
<= 3% of Sr
Front material
PBT
electrical connection
Screw-clamp terminals, 4 x 1.5 mm²
output circuit type
DC
Sensing range
> 15...40 mm
Sensor type
Inductive proximity sensor
Voltage drop
<2 V (closed)
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Safety level
SIL 2 conforming to IEC 61508, PL = d conforming to ISO 13849-1, SILCL 2 conforming to IEC 62061
Sensor design
Form 40 x 40 x 117
Status led
Supply on: 1 LED (green), output state: 1 LED (yellow)
Wiring technique
4-wire
Size
117 mm
Type of output signal
Discrete
Environment
Directives
2014/34/EU - ATEX directive
ip degree of protection
IP67 conforming to IEC 60529, IP65 conforming to IEC 60529
Range of product
Telemecanique Inductive proximity sensors XS
Dust zone
Zone 21 - 22
standards
IEC 60079-31IEC 60079-0
vibration resistance
25 gn amplitude = +/- 2 mm (f = 10-55 Hz) conforming to IEC 60068-2-6