Main
Body type
Fixed
Series name
General purpose
sensor name
XS6
Complementary
cable composition
4 x 0.11 mm²
Product certifications
CSAUL
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Current consumption
<= 10 mA no-load
detection face
Frontal
marking
CE
Discrete output function
1 NO + 1 NC
Enclosure material
Stainless steel 303
Detector flush mounting acceptance
Flush mountable
Differential travel
1...15 % of Sr
Material
Stainless steel
switching frequency
<= 2500 Hz
Discrete output type
PNP
switching capacity in ma
<= 200 mA DC with overload and short-circuit protection
Front material
PPS
thread type
M8 x 1
electrical connection
Cable
output circuit type
DC
Sensing range
> 0...2.5 mm
Sensor type
Inductive proximity sensor
Voltage drop
<2 V (closed)
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Sensor design
Cylindrical M8
Status led
Output state: 1 LED (yellow)
Wiring technique
4-wire
Size
51 mm
Type of output signal
Discrete
Wire insulation material
PVC
Environment
ip degree of protection
IP67 conforming to IEC 60529
Range of product
Telemecanique Inductive proximity sensors XS
vibration resistance
25 gn amplitude = +/- 2 mm (f = 10-55 Hz) conforming to IEC 60068-2-6