Main
Body type
Fixed
Series name
Fail safe inductive sensor
sensor name
XS1
Complementary
Product certifications
TÜVE2cULus
[us] rated supply voltage
12...24 V DC with reverse polarity protection
Current consumption
0...10 mA no-load
detection face
Frontal
marking
CEUKCA
Device application
Mobile equipment
Discrete output function
1 NO + 1 NC
Enclosure material
Nickel plated brass
Detector flush mounting acceptance
Flush mountable
safety reliability data
MTTFd = 2422 years, PFHd = 47.1E-9 1/h, SFF = 98.9%, DC > 96 % with appropriate safety controller
Differential travel
1...15 % of Sr
Material
Metal
switching frequency
<= 85 Hz
Discrete output type
PNP
switching capacity in ma
<= 200 mA with overload and short-circuit protection
Front material
PPS
thread type
M18 x 1
electrical connection
Male connector M12, 4 pins
output circuit type
DC
Sensing range
8...15 mm
Sensor type
Inductive proximity sensor
Voltage drop
<2 V (closed)
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Safety level
SIL 2 conforming to IEC 61508, PL = d conforming to ISO 13849-1, SILCL 2 conforming to IEC 62061
Sensor design
Cylindrical M18
Status led
Output state: 1 LED (yellow)
Wiring technique
4-wire
Size
50 mm
Type of output signal
Discrete
Environment
ip degree of protection
IP69K conforming to DIN 40050, IP65 conforming to IEC 60529, IP67
Range of product
Telemecanique Inductive proximity sensors XS
standards
IEC 62061ISO 13849-1
vibration resistance
25 gn amplitude = +/- 2 mm (f = 10-55 Hz) conforming to IEC 60068-2-6