Main
Fluid connection type
SAE 7/16-20UNF-2A (male)
controlled fluid
Fresh water (0-135 °C), air (-40-135 °C), hydraulic oil (-40-135 °C), gas (-40-135 °C), refrigeration fluid (-40-135 °C)
Type of packing
Individual
pressure sensor name
XMLP
pressure sensor type
Pressure transmitter
Complementary
Accuracy
0.1 % of the measuring range
local display
Without
Product certifications
CERCMcULus
Product or component type
Electronic pressure sensors
[us] rated supply voltage
12...24 V DC SELV (voltage limits: 7-33 V)
Analogue output function
4...20 mA, 2-wire
Current consumption
< 23 mA
Quantity per set
Set of 1
Drift of the sensitivity
+/- 0,02 % of measuring range/°K
Drift of the zero point
+/- 0,02 % of measuring range/°K
Electrical circuit type
Control circuit
measurement accuracy
+/- 0,5 % de la plage de mesure
Operating position
Any position
Materials in contact with fluid
Stainless steel AISI 316L
electrical connection
1 male connector M12 4 pins
Shock resistance
100 gn for 11 ms conforming to IEC 60068-2-27
Response time on output
<= 2 ms 10...90 % of full scale
Type of output signal
Analogue
Protection type
Load short-circuitreverse polarity
Environment
ip degree of protection
IP65 conforming to IEC 60529, IP67 conforming to IEC 60529, IP69K conforming to IEC 60529
Range of product
Telemecanique Pressure sensors XM
electromagnetic compatibility
Electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 4 kV contact, 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 1 kV 42 Ohm, immunity to magnetic fields conforming to IEC 61000-4-8 100 A/m 50 Hz, electrical fast transient/burst immunity test conforming to IEC 61000-4-4 4 kV, susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...3000 MHz, radiated RF fields conforming to IEC 61000-4-6 10 V 0.01...80 MHz
standards
IEC 61326-2-3NSF ANSI 61
vibration resistance
20 gn (f = 15-2000 Hz) conforming to IEC 60068-2-6
protective treatment
TC