Main
design
Slim
Signalling circuit voltage
24 V
Solenoid contacts type and composition
3 NC (slow-break, break before make)
component name
XCSLF
head type
Key operated turret head
Complementary
Product certifications
CSATÜVUL
Product or component type
Safety switch
[us] rated supply voltage
24 V - 15...10 %
Actuator forcible withdrawal rtc
3000 NEWTON
Locking options description
With interlocking, locking by solenoid
contact operation
Slow-break, break before make
Contacts type and composition
3 NC
Electrical shock protection class
Class I conforming to IEC 61140
safety reliability data
B10d = 5500000 value given for a life time of 20 years limited by mechanical or contact wear
body material
Zamak
Material
Metal
Local signalling
1 LED (orange) for actuator withdrawn, 1 LED (green) for actuator inserted and locked
head material
Zamak
Electromagnet interlocking
Locking on energisation and unlocking on de-energisation of solenoid
Positive opening
With NC contact
electrical connection
Male connector M23, 19 pins
Maximum load current
<= 15 A
Operating rate
10 cyc/mn for maximum durability
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach SIL 3 conforming to IEC 61508
Supply frequency
50/60 Hz
Signalling circuit type
AC/DC
Supply voltage type
AC/DC
Environment
ip degree of protection
IP65 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Range of product
Telemecanique Safety switches XCS
standards
CSA C22.2 No 14UL 508IEC 62061IEC 60947-5-1ISO 13849-1EN 1088/ISO 14119IEC 60204-1
vibration resistance
5 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
protective treatment
TC