Kõik kategooriad
Võrdle Ostukorv
HDA101L - MCCB h3 x160 TM 4x100A 18kA - Hager - MCCB h3 x160 TM 4x100A 18kA - Hager - 0
HDA101L - MCCB h3 x160 TM 4x100A 18kA - Hager - MCCB h3 x160 TM 4x100A 18kA - Hager - 0
Tellimisel

HDA101L – Hager

122,46 € KM-ta
151,86 € KM-ga
MCCB h3 x160 TM 4x100A 18kA - Hager
151,86 €
SPETSIFIKATSIOONID
Additional Information
type of order Toggle
type of pole 4P4D
Main
Number of modules 6
rated operational voltage ue 220 / 415 V
Complementary
air humidity protection for all climates
breaking capacity on 1 pole for it 230v nf 60947-2 15 kA
category of use A
complete device with protection unit Yes
connection cross-sect. flexible conductor 4 / 70mm²
correction factor of rating current for 2 devices placed side-by-side 1
din rail mounting with optional adaptator No
electric endurance in number of cycles 1000
magnetic trip delay time 0 ms
motor drive optional No
power loss per pole at in 13 W
range of the magnetic adjustment 1500 A
thermal protection trip time 0 ms
[in] rated current 100 A
breaking capacity on 1 pole for it 400v nf 60947-2 9 kA
connection cross-sect. rigid cable 4 / 95mm²
correction factor of rating current for 3 devices placed side-by-side 1
integrated earth fault protection No
number of mechanical operations 4000
setting type in or ith IN
time of response when opening 10 ms
total power loss under in 39 W
trip unit TM F/F
correction factor of rating current for 4 and 5 devices placed side-by-side 1
tripmode TM
type of connection with screw
with under voltage release No
correction factor of rating current for 6 devices placed side-by-side 1
rated service breaking capacity ics ac according iec 60947-2 100 %
storage/transport temperature -35…70 °C
rated ultimate short-circuit breaking capacity icu under 230v ac iec 60947-2 25 kA
Rated insulation voltage 690 V
rated ultimate short-circuit breaking capacity icu under 240v ac iec 60947-2 25 kA
connection Front connection
rated ultimate short-circuit breaking capacity icu under 400v ac iec 60947-2 18 kA
rated ultimate short-circuit breaking capacity icu under 415v ac iec 60947-2 18 kA
rated ultimate short-circuit breaking capacity icu under 440v ac iec 60947-2 15 kA
rated ultimate short-circuit breaking capacity icu under 690v ac iec 60947-2 4 kA
thermal protection nob setting xin 1
thermal setting current on neutral pole 1 In
frequency 50/60
rated impulse withstand voltage 8 kV
Poles description 4 P
Environment
altitude 2000 m
european directive weee concerned
protection index ip IP4X
standard text IEC 60947-2
operating temperature -25…70 °C
KKK ja hinna lisateave

Võta meiega ühendust

Professionaalne elektriseadmete müük Eestis, Lätis, Leedus ja Soomes. Sertifitseeritud madalpinge komponendid, kaitselülitid, kontaktorid ja tööstusautomaatika lahendused. Sama päeva hinnapakkumised ja kiire tarne Baltikumis ja Soomes

Baltelec
+372 5326 4976

E–R 9:00–17:00

info@baltelec.ee

Vastame 2 tunni jooksul

HDA101L Hager on lahendus kategooriast Kaitselülitid, mis on mõeldud professionaalidele. BaltElec tegeleb hulgimüügi ja distributsiooniga Eestis, Lätis, Leedus ja Soomes.

  • Autentne Hager toode, sertifikaadid ja vastavusdokumendid saadaval.
  • Mahupõhine hinnastus – küsi pakkumist suuremate koguste jaoks (võimalik, et sätestame MOQ).
  • Tõhus ja kiire logistika Baltikumis ning Soomes; koostöö logistikapartneritega.
  • Tehniline tugi ja nõustamine valikul vastavalt Sinu rakendusele.

Hind: Küsi eripakkumist. Hind sõltub kogusest, tarne- ja maksetingimustest.

KKK tootele HDA101L - Hager

Hiljuti vaadatud
HDA101L - Hager
MCCB h3 x160 TM 4x100A 18kA
122,46 € KM-ta
151,86 € KM-ga
Tellimisel