Default
Seeria
TeSyS Deca juhtreleed
Main
Range
TeSys
TeSys Deca
[uc] control circuit voltage
48 V AC 50/60 Hz
job category
AC-15
DC-13
AC-14
name of the device
CAD
switch application
Remote
type of product or equipment
Changeover relay for VMC
composition of the poles
3 F + 2 O
Product Name
TeSys CAD
[ui] rated insulation voltage
600 V UL certified
600 V CSA certified
690 V conforming to IEC 60947-5-1
control circuit type
AC at 50/60 Hz
Complementary
[ue] rated operational voltage
<= 690 V CA 25...400 Hz
[icw] rated short-time withstand current
100 A - 1s
120 A - 500 ms
140 A - 100 ms
[ith] conventional thermal current
10A at <60°C)
caliber of the fuse to be associated
10 A gG conforming to IEC 60947-5-1
Handle front plate colour
99 mm
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947
average fuel consumption when going
8VA 50Hz (at 20°C)
minimum switching current
5 mA
product weight
0,58 kg
connection mode
Spring terminals 1 cable(s) 1...2.5 mm²flexible without cable end Spring terminals
2 cable(s) 1...2.5 mm²flexible without cable end Spring terminals
1 cable(s) 1...2.5 mm²rigid without cable end
Spring terminals 2 cable(s) 1...2.5 mm²rigid without cable end
control circuit voltage range
0.3...0.6 Uc -40...70 °C dropout AC 50/60 Hz
0.8...1.1 Uc -40...60 °C operational AC 50 Hz
0.85...1.1 Uc -40 …60 °C operational AC 60 Hz
1...1.1 Uc 60…70 °C operational AC 50/60 Hz
mechanical endurance
30 Mcycles
width (w)
45 mm
mechanical robustness
Shock control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shock control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27
Vibration control relay open: 2 Gn, 5 at 300 Hz conforming to IEC 60068-2-6
Vibrations control relay closed: 4 Gn, 5 at 300 Hz conforming to IEC 60068-2-6
rated rms inrush power
140 A AC conforming to IEC 60947-5-1
250 A DC conforming to IEC 60947-5-1
depth
84 mm
mounting bracket
Platine
Rail
calling power goes
70VA 50Hz (at 20°C)
operating time
12…22 ms excitation bobine + fermeture "F"
4…12 ms désexcitation bobine + ouverture "F"
4…19 ms excitation bobine + ouverture "O"
6…17 ms désexcitation bobine + fermeture "O"
max command speed
180 cyc/mn
minimum switching voltage
17V
non-overlap time
1.5 ms on excitation between NC and NO contact
1.5 ms on de-excitation between NC and NO contact
Environment
ip degree of protection
IP2x front panel conforming to VDE 0106
operating altitude
0...3000 m
product certificates
UL
CSA
UKCA
standards
BS 4794
EN 60947-5
CEI 60947-5-1
NF C 63-140
VDE 0660
CEI 60335-1
operating temperature
-40…60 °C
60…70 °C with current reduction
storage room temperature
-60…80 °C
protective treatment
TH conforming to IEC 60068
insulation resistance
> 10 MΩ