Kõik kategooriad
Võrdle Ostukorv
C10W46E040 - Kaitselüliti, ComPacT NSX100HB2, 100kA/690VAC, 4P, MicroLogic 6.2E väljalülitusseade 40A - Schneider Electric - Kaitselüliti, ComPacT NSX100HB2, 100kA/690VAC, 4P, MicroLogic 6.2E väljalülitusseade 40A - Schneider Electric - 0
C10W46E040 - Kaitselüliti, ComPacT NSX100HB2, 100kA/690VAC, 4P, MicroLogic 6.2E väljalülitusseade 40A - Schneider Electric - Kaitselüliti, ComPacT NSX100HB2, 100kA/690VAC, 4P, MicroLogic 6.2E väljalülitusseade 40A - Schneider Electric - 0
Tellimisel

C10W46E040 – Schneider Electric

EAN: 3606482013759
885,43 € KM-ta
1 097,93 € KM-ga
Kaitselüliti, ComPacT NSX100HB2, 100kA/690VAC, 4P, MicroLogic 6.2E väljalülitusseade 40A - Schneider Electric
1 097,93 €
SPETSIFIKATSIOONID
Main
Range New generation ComPacT
sectioning ability Yes conforming to EN/IEC 60947-2
job category Category A
name of the device NSX100HB2
type of product or equipment Circuit breaker
Product Name Next Generation ComPacT NSX
[ui] rated insulation voltage 800 V AC 50/60 Hz
trigger protection functions LSIG
circuit breaker installation mode Fixed
performance level HB2 100 kA 690 V AC
neutral pole position Left
trigger name Micrologic 6.2 E
type of trigger Electronic
ultimate short-circuit breaking capacity [icu] 100 kA Icu at 500 V AC 50/60 Hz if conforming to CEI 60947-2
100 kA Icu at 525 V AC 50/60 Hz if conforming to CEI 60947-2
100 kA Icu at 660/690 V AC 50/60 Hz if comply with IEC 60947-2
protected poles 4d
3D + OSN
3d + N/2
3d
Complementary
"no" connection 35 mm
[in] rated operational current 40 A at 40 °C
[ue] rated operational voltage 690 V AC 50/60 Hz
application Distribution
[ics] rated service breaking capacity 100 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
100 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
short-time protection threshold setting range [isd] 1.5 to 15 x In
Handle front plate colour 161 mm
trigger caliber 40 A at 40 °C
[uimp] rated impulse withstand voltage 8 kV
earth protection time delay setting range [tg] 0…0,4 s I²t=off
0,1…0,4 s I²t=on
product weight 2,4 kg
earth fault protection threshold setting range [ig] 0,4…1 x In
Activation Ig on/off
tsd short time protection time delay setting Adjustable
electrical life 20000 cycles at 440 V In/2
10000 cycles at 440 V In
10000 cycles at 690 V In/2
5000 cycles at 690 V In
setting the differential protection time delay δt Adjustable
type of measurement energy meter
Data recording Protection and alarm parameters
Stamping time histories and event tables
Power quality
Maximum/minimum meters Maintenance
indicators
Current and power
demand Instantaneous and demand values
​​Energy measurement
mechanical endurance 20000 cycle
width (w) 140 mm
network frequency 50/60 Hz
thermal memory 20 minutes before and after triggering
Local signalling for ready to operate Flashing LED (green)
for overload 105% Ir LED (red)
for overload 90% Ir LED (orange)
setting the earth fault protection time delay tg Adjustable 5 positions
long time protection time delay setting range [tr] 15…400 s at 1.5 x Jump
0.5…16 s at 6 x Jump
0.35…11 s at 7.2 x Jump
short time protection time delay setting range [tsd] 0…0,4 s I²t=off
0,1…0,4 s I²t=on
setting range of the long-time protection threshold [ir] (thermal protection) 18...40 A
upstream connection Façade
downstream connection Façade
instantaneous protection threshold setting range [ii] (short-circuit protection) 1.5 to 15 x In
number of slots for electrical auxiliaries 5 slot(s)
ig earth fault protection sensor setting Adjustable 9 positions
mounting bracket back plate
depth (p) 86 mm
Network type THAT
differential protection Without
mounting position Horizontal et vertical
Flat on the back
power loss per pole 1.34W
tr long time protection time delay setting Adjustable
instantaneous protection sensor setting ii (short circuit protection) Adjustable
ir long time protection sensor setting (thermal protection) Adjustable 9 positions
order type Just a little bit
type of display LCD display
kind of protection L: for overload protection (long delay)
S: for short delay protection
I: for instantaneous short-circuit
protection G: for short-circuit to ground protection
zsi logic selective latch area With
Poles description 4P
Environment
degree of pollution 3 conforming to IEC 60664-1
ip degree of protection IP40 conforming to CEI 60529
operating altitude 0...2000 m without current reduction
2000 m...5000 m with current reduction
product certificates Marine
CCC
EAC
class of protection against electric shock Class II
operating ambient temperature -25…70 °C
overvoltage category Class II
standards EN/CEI 60947
relative humidity 0…95%
shock resistance ik IK07 conforming to IEC 62262
storage room temperature -40…85 °C
KKK ja hinna lisateave

Võta meiega ühendust

Professionaalne elektriseadmete müük Eestis, Lätis, Leedus ja Soomes. Sertifitseeritud madalpinge komponendid, kaitselülitid, kontaktorid ja tööstusautomaatika lahendused. Sama päeva hinnapakkumised ja kiire tarne Baltikumis ja Soomes

Baltelec
+372 5326 4976

E–R 9:00–17:00

info@baltelec.ee

Vastame 2 tunni jooksul

C10W46E040 Schneider Electric on toode kategooriast Compact NSX, mis on mõeldud ettevõtetele. BaltElec tegeleb mahupõhise müügi ja toodete levitamisega Eestis, Lätis, Leedus ja Soomes.

  • Originaal Schneider Electric toode, sertifikaadid ja vastavusdokumendid saadaval.
  • Projektihind – küsi pakkumist suuremate koguste jaoks (võimalik, et sätestame MOQ).
  • Kiire tarne Baltikumis ning Soomes; koostöö tunnustatud kulleritega.
  • Tehniline tugi ja ettepanekud sobivuse kohta vastavalt Sinu rakendusele.

Hinnainfo: Küsi eripakkumist. Hind sõltub kogusest, tarne- ja maksetingimustest.

KKK tootele C10W46E040 - Schneider Electric

Hiljuti vaadatud
C10W46E040 - Schneider Electric
Kaitselüliti, ComPacT NSX100HB2, 100kA/690VAC, 4P, MicroLogic 6.2E väljalülitusseade 40A
885,43 € KM-ta
1 097,93 € KM-ga
Tellimisel