Main
power supply module output current
1,25 A
product range
Alimentation Modicon
type of product or equipment
power supply
nominal power in w
30W
rated input voltage
100...240 V AC single-phase
100...240 V AC 2-phase
kind of power supply
Regulated switching mode
optional variant
Modular
Complementary
18 mm pitches
0.48 at 115 V AC
0.38 at 230 V AC
feed
SELV conforming to EN/IEC 60950-1
SELV conforming to EN/IEC 60204-1
SELV conforming to IEC 60364-4-41
power consumption
< 0,8 A 115 V CA
< 0,6 A 230 V CA
output coupling
Parallel Series
Handle front plate colour
91 mm
maximum leakage current
0.25mA 240V AC
case material
Plastic
inrush current
25 A at 115 V
50 A at 230 V
expected capacitor life
10 year(s)
product weight
0,170 kg
starting with capacitive loads
3000 µF
led status
1 LED (green) output voltage
connection mode
Screw connection: 0.5...1.5 mm², (4 x 1.5 mm² + 2 x 1 mm² + 2 x 0.14 mm²) without cable end for input/output
Screw connection: 0.5...1 mm², (AWG 20 to AWG 18) with cable end ferrule for input/output
nominal network frequency
50…60 Hz
output voltage
24 V CC
width (w)
36 mm
input voltage limits
90 to 264 V AC
line and load regulation
< 0,5 % network in line
< 1 % network 0 to 100 % load
residual ripple
< 100 mV
depth
55,6 mm
mounting bracket
Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
DIN double profile rail
panel mounting
power dissipation in w
5W
yield
87% at 115V AC
87% at 230V AC
output voltage adjustment
24...28V
compatible network system
TN
TT
IT
mataining time
> 20 ms 115 V CA
> 60 ms 230 V CA
start-up time
< 2 s
mean time between failures (mtbf)
2500000 H at 25 °C, pleine charge
1000000 H at 55 °C, charge 80%
dielectric strength
3000 V AC input/output
output protection type
Against overload and short-circuits, protection technology: automatic reset
Against overheating, protection technology: manual reset
Against overvoltage, protection technology: manual reset
input protection type
Integrated fuse (not interchangeable) 3.15 A
External protection (recommended) 20 A Curve B
External protection (recommended) 20 A Curve C
External protection (recommended) 4 A Curve B
External protection (recommended) 4 A Curve C
Environment
degree of pollution
2
ip degree of protection
IP20
operating altitude
< 2000 m overvoltage category III
2000 m...5000 m overvoltage category II
product certificates
CE
cUL Listed cUL
Recognized
RCM
Scheme CB
EAC
KC
NEC: Class 2
ambient air temperature for operation
-25…55 °C without current derating mounting position A < 2000 m
55…70 °C with 2.67 % current derating per °C mounting position A < 2000 m
class of protection against electric shock
Class II without PE connection
standards
EN 62368-1
EN/CEI 61010-1
EN 61010-2-201
EN/CEI 61204-3
EN 61000-6-1
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
EN 61000-3 -2
EN 61000-3-3
UL 62368-1
UL 61010-1
UL 61010-2-201
CSA C22.2 No 62368-1
CSA C22.2 No 61010-1
CSA C22.2 No 61010-2-201
EN/ IEC 62368-1
mechanical shock resistance
100 m/s² pour 11 ms
electromagnetic emission
Conducted emissions conforming to EN 61000-6-3
Radiated emissions conforming to EN 61000-6-4
vibration resistance
3 mm (f= 2...9 Hz) conforming to IEC 60721-3-3
10 m/s² (f= 9...200 Hz) conforming to IEC 60721-3-3
electromagnetic immunity
Immunity to electrostatic discharge - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
Immunity to electrostatic discharge - test level: 9 kV (air discharge) conforming to EN/ IEC 61000-4-2
Electromagnetic field immunity test - test level: 10 V/m (80 MHz...2 GHz) conforming to EN/IEC 61000-4-3
Electromagnetic field immunity test - test level: 5 V/m (2...2.7 GHz) conforming to EN/IEC 61000-4-3
Electromagnetic field immunity test - test level: 3 V/m (2.7...6 GHz) ) conforming to EN/IEC 61000-4-3
Immunity to fast transients - test level: 4 kV (on input-output) conforming to EN/IEC 61000-4-4
Surge immunity test - test level: 3 kV (between supply and earth) conforming to EN/IEC 61000-4-5
Surge immunity test - test level: 1.5 kV (between phases) conforming to EN/IEC 61000-4-5
Immunity to conducted disturbances - test level: 10 Vrms (0.15 to 80 MHz) conforming to EN/IEC 61000-4-6
Immunity to magnetic fields - test level : 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8
Immunity to voltage drops - test level : 100 % (1 cycle) conforming to EN/IEC 61000-4-11
Immunity to voltage drops - test level: 60 % (10 cycles) conforming to EN/IEC 61000-4-11
Immunity to voltage drops - test level: 30 % (25 cycles) conforming to EN/IEC 61000-4-11
Disturbance field emission conforming to EN 55016-2-3
Harmonic current emission limitation conforming to to EN 61000-3-2 Conducted disturbance emission
conforming to EN 55016-1-2 Conducted
disturbance emission conforming to EN 55016-2-1